![Huawei Quidway NetEngine40E Configuration Manual - Reliability Download Page 794](http://html.mh-extra.com/html/huawei/quidway-netengine40e/quidway-netengine40e_configuration-manual-reliability_169453794.webp)
–
On the PE, run:
map
vsivsi-name
The MA is bound to a VSI.
e.
Run:
mep mep-id
The MEP is configured.
f.
Run:
remote-mep mep-id
mep-id
The remote MEP ID is configured.
g.
Run:
mep ccm-send enable
The CCM transmission function is enabled.
h.
Run:
remote-mep ccm-receive
[
mep-id
mep-id
]
enable
The CCM reception function is enabled.
2.
Table 8-54
Enabling the 1DM frame reception function
Scenario
Procedure
Point-to-
point
Non-test instance-based statistics collection by an interface-based
MEP
Run:
delay-measure one-way receive
mep
mep-id
The 1DM frame reception function is enabled.
Performance statistics collection based on a specified test instance:
1. Run:
test-id
test-id
A test instance is configured.
2. Run:
delay-measure one-way receive
test-id
test-id
The 1DM frame reception function is enabled.
Point-to-
multipoint
1. Run:
test-id
test-id
A test instance is configured.
2. Run:
delay-measure one-way receive
test-id
test-id
The 1DM frame reception function is enabled.
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
8 Ethernet OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
777