eth-trunk 2
lacp priority 2000
cfm md md1 ma ma1 remote-mep mep-id 2 trigger if-down
#
interface GigabitEthernet1/0/2
eth-trunk 2
lacp priority 2000
cfm md md1 ma ma2 remote-mep mep-id 4 trigger if-down
#
interface GigabitEthernet1/0/3
eth-trunk 2
cfm md md1 ma ma3 remote-mep mep-id 6 trigger if-down
#
cfm md md1
ma ma1
ccm-interval 10
mep mep-id 1 interface GigabitEthernet1/0/1 outward
mep ccm-send mep-id 1 enable
remote-mep mep-id 2
remote-mep ccm-receive mep-id 2 enable
ma ma2
ccm-interval 10
mep mep-id 3 interface GigabitEthernet1/0/2 outward
mep ccm-send mep-id 3 enable
remote-mep mep-id 4
remote-mep ccm-receive mep-id 4 enable
ma ma3
ccm-interval 10
mep mep-id 5 interface GigabitEthernet1/0/3 outward
mep ccm-send mep-id 5 enable
remote-mep mep-id 6
remote-mep ccm-receive mep-id 6 enable
#
return
Example for Associating EFM OAM with Ethernet CFM
In this example, by configuring EFM OAM and Ethernet CFM, you can implement the fault
notification.
Networking Requirements
, configure EFM OAM to run between Router A and Router B, and
between Router C and Router D; configure Ethernet CFM to run between Router B and Router
C. This implements end-to-end link detection. When a fault occurs on the link between Router
A and Router B, Ethernet CFM is triggered to send alarms of the fault to Router D.When a fault
occurs on the link between Router C and Router D, Ethernet CFM is triggered to send alarms
of the fault to Router A.
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
8 Ethernet OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.