Table 26 Error Codes — Part Code 1005
(continued)
Failure
Level
Severity
Level
Recommended Action
Error Message
Error
Number
Part
Code
6
E
The configuration information
has been already changed.
Check the settings, and
request the setting of the
configuration information
again.
High Speed mode/MIX mode
was specified. However,
there are addresses to which
High Speed mode/MIX mode
cannot be set in the Fibre
Addresses of the specified
ports.
1203
1005
6
E
The configuration information
has been already changed.
Check the settings, and
request the setting of the
configuration information
again.
High Speed mode/MIX mode
was specified. However,
there are topologies to which
High Speed mode/MIX mode
cannot be set in the
topologies of the specified
ports.
1204
1005
6
E
To add a path, change the
attribute of the specified port
to Target or RCU Target.
You could not add the path
to the initiator or external
port.
1350
1005
6
E
Cannot set to high-speed
mode because the port
attributes are mixed, or
cannot set to internal/external
mix mode because the
combination of port attributes
is different. Check the port
attributes, and then retry the
operation.
The high-speed or
initiator/external mix mode
cannot be set to the specified
port because of the attribute
of the port.
1351
1005
6
E
Because the port you are
trying to set is for XP
Continuous Access, you must
delete the logical path, and
then retry the port setting.
Logical paths remain on the
Fibre-MCU port. This
operation may cause a fatal
damage to the logical paths.
Please stop this operation. If
you want to continue this
operation, please remove the
logical paths from the MCU
port first.
1352
1005
6
E
Because the port you are
trying to set is for XP
Continuous Access, you must
delete the S-VOL logical path
that is set to RCU Target, and
then retry the port setting.
S-VOLs remain on the
Fibre-RCU port. This
operation may cause a fatal
damage to S-VOLs. Please
stop this operation. If you
want to continue this
operation, please remove the
S-VOLs from the RCU port
first.
1353
1005
6
E
To register the WWN,
change the attribute of the
specified port to Target or
RCU Target.
You could not register the
WWN to the initiator or
external port.
1354
1005
6
E
To change the host mode,
change the attribute of the
specified port to Target or
RCU Target.
You could not change the
host mode of the host group
that you connected to the
initiator or external port.
1355
1005
6
E
To add the host group,
change the attribute of the
specified port to Target or
RCU Target.
You could not add the host
group to the initiator or
external port.
1356
1005
110