Table 64 Error Codes — Part Code 7105
(continued)
Failure
Level
Severity
Level
Recommended Action
Error Message
Error
Number
Part
Code
0
i
Detach the S-VOL from the
host, or delete the XP
Continuous Access path.
You cannot reserve the
volume, because a path
group is set.
8511
7105
0
i
Vary the S-VOL offline from
the mainframe host, and then
issue the command again.
Cannot perform Resync or
Suspend operation because
of the path group setting.
8512
7105
0
i
Vary the S-VOL offline from
the mainframe host, and then
issue the command again.
The command has been
rejected, because the
specified S-VOL is used by the
host.
8513
7105
0
i
Delete the Reserve volume.
No reserved volume can be
allocated.
8514
7105
0
i
Check the contents, and retry.
The number of cylinders in the
reserved volume exceeds the
maximum.
8515
7105
0
i
Check the contents, and retry.
The number of S-VOL
cylinders exceeds the
maximum.
8516
7105
0
i
Check the contents, and retry.
The number of T-VOL
cylinders exceeds the
maximum.
8517
7105
0
i
Check the emulation type.
You cannot create a pair,
because the track format is
different for each. Make sure
that the specified emulation
type is the same for both.
8518
7105
0
i
Check the volume capacity.
You cannot set a pair
because the number of
cylinders is different for each.
Make sure that the capacity
is the same for both.
8519
7105
0
i
Specify the volume with the
same emulation type, and
retry the operation.
You cannot set a pair,
because the volume type is
different for each.
8520
7105
0
i
Check the contents, and retry.
The number of multiple copy
jobs exceeded the maximum.
8521
7105
0
i
Specify the supported
emulation type.
The emulation type of the
S-VOL is not supported.
8522
7105
0
i
Specify the supported
emulation type.
The emulation type of the
T-VOL is not supported.
8523
7105
0
i
Specify the supported
emulation type.
The emulation type is not
supported.
8524
7105
0
E
Call HP technical support.
An internal logic error
occurred.
8525
7105
0
E
Call HP technical support.
An internal logic error
occurred.
8526
7105
0
E
Call HP technical support.
An internal logic error
occurred.
8527
7105
Remote Web Console Error Codes