Table 54 Error Codes — Part Code 6505
(continued)
Failure
Level
Severity
Level
Recommended Action
Error Message
Error
Number
Part
Code
0
W
Check the following for the
specified primary data
volume:
•
The volume is an M-VOL
of a synchronous pair or
an XP External Storage
Access Manager pair,
and the pair status is in
PAIR or Duplex when it is
referenced from the XP
Continuous Access
window, the TrueCopy for
Mainframe window, RAID
Manager, or Business
Continuity Manager.
•
The volume is an R-VOL of
a synchronous pair or an
XP External Storage
Access Manager pair,
and the pair status is in
SSWS or Swapping when
it is referenced from RAID
Manager or Business
Continuity Manager.
Delta resync operation failed
because the specified
primary data volume was not
a data volume of XP
Continuous Access or
TrueCopy for Mainframe, or
the pair status of the primary
data volume was invalid.
58685
6505
0
W
Check the attribute of the
journal group of the remote
storage system.
The specified operation failed
because the attribute of the
journal group of the remote
subsystem was not restore.
58686
6505
0
W
If the problem persists despite
retrying, call HP technical
support.
The status of the other mirror
of the Delta resync did not
change.
58687
6505
0
W
Check the status of the
specified primary data
volume.
Delta resync failed because
the specified primary data
volume was not ready for
Delta resync.
58688
6505
0
W
Check the status of the
mirrors in the specified
journal group.
The operation failed because
the status of some mirrors in
the master or restore journal
group is invalid. Check the
status of the mirrors in the
specified journal group.
58689
6505
300 Remote Web Console for Storage System Messages and Error Codes