Table 54 Error Codes — Part Code 6505
(continued)
Failure
Level
Severity
Level
Recommended Action
Error Message
Error
Number
Part
Code
0
i
Check the specified Suspend
Condition parameter.
Invalid parameter (Suspend
Condition-Master Journal
Failure).
58070
6505
0
i
Check the specified Suspend
Condition parameter.
Invalid parameter (Suspend
Condition-Restore Journal
Failure).
58071
6505
4
W
The current configuration of
the storage systems and the
current status of lines
connecting the storage
systems may not satisfy the
operating conditions. Check
the configuration of the
storage systems and the
status of lines connecting the
storage systems, and then
check whether the status of
the XP Continuous Access
pair is changed.
The pair status has not
changed yet. Check the
configuration of the
subsystems and the status of
lines connecting the
subsystems, and then check
whether the status of the XP
Continuous Access pair is
changed.
58072
6505
0
W
If the error occurs after
retrying, call HP technical
support.
The subsystem is busy. Wait
for a while, and then retry the
operation.
58073
6505
0
i
Check the specified serial
number.
The specified serial number
is incorrect.
58075
6505
0
i
Check the status of the
specified volume.
The specified volume does
not exist or is unusable.
58078
6505
0
i
Check the status of the
specified primary data
volume in the Volume
Retention Manager window
or the Data Retention Utility
window.
The specified primary data
volume cannot be used as an
S-VOL (secondary volume)
because of Volume Retention
Manager settings or Data
Retention Utility settings.
58079
6505
0
i
Check the status of the
specified primary data
volume.
A Concurrent Copy operation
is in progress on the specified
primary data volume.
58080
6505
0
i
Check the status of the
specified volume in the
Volume Security window.
The specified primary data
volume belongs to an access
group or a pool group of
Volume Security.
58081
6505
0
i
Confirm the status of
consistency group in the
TrueCopy Asynchronous for
Mainframe, XP Continuous
Access Asynchronous, or XP
Continuous Access Journal
window of the local and
remote storage systems.
The specified consistency
group is being used. Confirm
the status of consistency
group in the TrueCopy
Asynchronous for Mainframe,
XP Continuous Access
Asynchronous, or XP
Continuous Access Journal
screen of the local and
remote storage systems.
58082
6505
0
i
Check the status of the
specified primary journal
group.
The specified primary journal
group is not registered.
58083
6505
Remote Web Console Error Codes 279