Table 61 Error Codes — Part Code 7005
(continued)
Failure
Level
Severity
Level
Recommended Action
Error Message
Error
Number
Part
Code
5
E
See the section describing
creating pairs and the pair
status in the HP
StorageWorks
XP24000/XP20000 Business
Copy Software User's Guide
for the relationship between
the status of pairs and the
commands that can be
accepted.
The command has been
rejected, because the
operation will not function
with the current pair status.
8505
7005
0
i
Vary the S-VOL or the
reserved volume offline from
the mainframe host, and then
issue the command again.
The command has been
rejected, because the
specified S-VOL or reserved
volume is used by the host.
8506
7005
0
i
You cannot execute the
Pairsplit command because
the pair is already in the
PSUS status.
The Pairsplit command was
issued to the pairs in a PSUS
status.
8507
7005
0
i
You cannot execute the
Pairsplit command because
the pair is already in the
PSUS status.
The Paircreate command was
issued to the pairs in a PSUS
status.
8508
7005
0
i
Check the contents, and retry.
The Split command with the
QUIESCE specification was
issued to a secondary boot
device.
8509
7005
0
i
Check the contents, and retry.
The M-VOL Suspend
command was issued to a
secondary boot device.
8510
7005
0
i
Detach the S-VOL from the
host, or delete the XP
Continuous Access path.
You cannot reserve the
volume, because a path
group is set.
8511
7005
0
i
Detach the S-VOL from the
host, or delete the XP
Continuous Access path.
Cannot perform Pairresync or
Pairsplit-E operation because
of the path group setting.
8512
7005
0
i
Vary the P-VOL offline from
the mainframe host, and then
issue the command again.
The command has been
rejected, because the
specified P-VOL is used by
the host.
8513
7005
0
i
Delete the Reserve volume.
No reserved volume can be
allocated.
8514
7005
0
i
Check the contents, and retry.
The number of cylinders in
the reserved volume exceeds
the maximum.
8515
7005
0
i
Check the contents, and retry.
The number of P-VOL
cylinders exceeds the
maximum.
8516
7005
0
i
Check the contents, and retry.
The number of S-VOL
cylinders exceeds the
maximum.
8517
7005
Remote Web Console Error Codes 347