Table 34 Error Codes — Part Code 3005
(continued)
Failure
Level
Severity
Level
Recommended Action
Error Message
Error
Number
Part
Code
6
E
Specify another logical
volume.
The specified logical volume
cannot be registered,
because an SCSI path is set
to the logical volume.
58466
3005
6
E
The current licensed capacity
is insufficient. Purchase a new
license key to increase the
licensed capacity.
The specified volume cannot
be set as a Pool-VOL,
because it exceeds the
licensed capacity.
58467
3005
6
E
Specify another logical
volume.
The emulation type of the
logical volume is incorrect.
58468
3005
6
E
Specify another logical
volume.
The specified logical volume
is being used by another
program product.
58469
3005
6
E
Add some pool-VOL, or
decrease the snapshot data
by restoring or deleting XP
Snapshot pairs.
The operation cannot be
done, because the usage of
the specified Pool is 100%
(full).
58470
3005
6
E
Install additional shared
memory for the V-VOL
management area.
The shared memory for the
V-VOL management area is
insufficient.
58471
3005
6
E
When the pool information
cannot be acquired, do the
following:
•
Check the installation
status of the V-VOL
management area, when
the V-VOL management
area is not initialized.
•
Check the installation
status of the V-VOL
management area, when
the V-VOL management
area is not installed.
Acquisition of the pool
information has failed.
Pool information cannot be
acquired when:
•
V-VOL management area
is not initialized.
•
V-VOL management area
is not installed.
58472
3005
6
E
Check the error message of
the logical volumes in the
Pool.
An error occurred when
setting the Pool. Check the
error message of the logical
volume(s) in the Pool.
58473
3005
6
E
Check the amount of free
space in Pool management
block in the Pool window.
Install additional shared
memory if the free space is
insufficient.
Call HP technical support if
the capacity of shared
memory is not insufficient.
The capacity of shared
memory is insufficient or an
error occurred during SVP
processing.
58474
3005
6
E
Install the PCB for fiber port
and retry the operation.
The PCB for fibre port is not
installed.
58475
3005
3
E
If this problem persists, call
HP technical support.
A communication time-out
error occurred in the storage
system. Wait for a while, and
then retry the operation.
58491
3005
Remote Web Console Error Codes
143