Table 58 Error Codes — Part Code 6610
(continued)
Failure
Level
Severity
Level
Recommended Action
Error Message
Error
Number
Part
Code
5
W
Check the amount of the
Preview data. If the amount
of the Preview data is too
large, clear the Preview data
by clicking [Apply], and then
retry the operation.
If the amount of Preview data
is small or there is no Preview
data, too much data is
selected. Reduce the number
of data, and retry the
operation.
The number of Preview data
may have exceeded the limit,
or too large number of data
is selected.
59115
6610
0
W
Check the microcode version
of the DKCMAIN, and then
call HP technical support.
The specified function is not
supported by the current
microprogram version.
59116
6610
0
W
Check the microcode version
of the DKCMAIN, and then
call HP technical support.
The current microprogram
version does not allow you to
change options for a journal
group in the Active status.
59119
6610
0
W
Check the microcode version
of DKCMAIN. If you want use
other emulation types, call HP
technical support and update
the microcode version of
DKCMAIN.
The current microcode
version of DKCMAIN does
not support Add Pair
(Paircreate) operations,
Resume Pair operations, and
Change Pair Option
operations using the
emulation type of the
specified volume.
59150
6610
0
W
To use a mainframe volume
as a journal volume, call HP
technical support and update
the microcode version of
DKCMAIN.
The current microprogram
version of DKCMAIN only
supports OPEN-V as the
emulation type of a journal
volume.
59151
6610
0
W
Check the emulation type of
the specified volume.
There are two or more kinds
of emulation types that
cannot be combined, in the
specified volume. Or you
tried to add a volume which
cannot be combined with the
emulation type of the existing
volume.
59152
6610
0
W
Change the status of the
mirror of the journal group to
Stop or Initial, and then retry
the operation.
The journal volume cannot be
deleted because the status of
the mirror of the journal
group is Active.
59153
6610
0
W
Check the number of journal
groups in the specified
extended consistency group
(EXCTG).
No more journal groups can
be added to the specified
extended consistency group
(EXCTG).
59321
6610
0
W
Check whether all extended
consistency groups (EXCTG)
are used by other program
products.
There are no valid extended
consistency groups (EXCTG).
59322
6610
Remote Web Console Error Codes 339