Table 67 Error Codes — Part Code 8105
Failure
Level
Severity
Level
Recommended Action
Error Message
Error
Number
Part
Code
6
E
Select another volume.
The specified volume cannot
be set as a command device
or a component of a LUSE
volume, because it is being
used as the volume of XP
Continuous Access, Business
Copy, Auto LUN, or XP
Snapshot. Select another
volume.
1002
8105
6
E
The configuration information
has been already changed.
Check the settings, and
request the setting of the
configuration information
again.
You are trying to set multiple
paths to the same volume
from one group.
1003
8105
6
E
The configuration information
has been already changed.
Check the settings, and
request the setting of the
configuration information
again.
Multiple volumes are
specified to a single port,
group or LUN combination.
1004
8105
6
E
Check the settings, and then
retry the operation.
The following volumes cannot
be specified when you
change the path
configurations:
•
Volumes that do not exist
•
Volumes other than the top
LUs in expanded LUs
•
Volumes reserved by Auto
LUN
•
System Disk volume
1005
8105
6
E
Check the setting.
Failed to remove the path.
The specified path is the last
path of the volumes used for
XP Continuous Access,
Business Copy, Auto LUN, or
XP Snapshot.
1007
8105
6
E
The configuration information
has been already changed.
Check the settings, and
request the setting of the
configuration information
again.
The emulation type of the
volumes is not for open
systems, or the volumes are
not mounted. Check the
setting.
1009
8105
2
E
If this problem persists, call
HP technical support.
An error occurred during SVP
processing. If this problem
persists, call HP technical
support.
1010
8105
396 Remote Web Console for Storage System Messages and Error Codes