Table 50 Error Codes — Part Code 6005
(continued)
Failure
Level
Severity
Level
Recommended Action
Error Message
Error
Number
Part
Code
0
W
Select another volume that is
not used by other program
products such as XP Business
Copy, XP Snapshot, and XP
Auto LUN, or cancel the use
of the volume operated by the
other program products and
retry the operation.
The Paircreate operation
failed because the specified
S-VOL, which is an XP Thin
Provisioning volume, is
already used by another
program product.
68757
6005
0
W
Check whether the specified
R-VOL is a System Disk.
The Add Pair (Paircreate)
operation failed because the
specified R-VOL is a System
Disk.
68758
6005
0
W
Check whether the specified
M-VOL is a System Disk.
The Add Pair (Paircreate)
operation failed because the
specified M-VOL is a System
Disk.
68764
6005
0
W
Install XP Continuous Access
to the storage system.
The operation failed because
the XP Continuous Access
function was not installed.
68787
6005
0
W
Install XP External Storage
Access Manager to the
storage system.
The operation failed because
the XP External Storage
Access Manager function
was not installed.
68788
6005
0
W
Install XP Continuous Access
to the RCU.
The Paircreate operation
failed because the XP
Continuous Access software
was not installed in the RCU.
68789
6005
0
W
Install XP External Storage
Access Manager to the RCU.
The Paircreate operation
failed because the XP
External Storage Access
Manager function was not
installed in the RCU.
68790
6005
0
W
Refresh the window, and
confirm whether the specified
volume is an S-VOL.
The operation failed because
the specified volume was not
an S-VOL.
68791
6005
0
W
Refresh the window, and
confirm whether the specified
volume is an XP External
Storage Access Manager
pair volume.
The operation failed because
the specified volume was not
an XP External Storage
Access Manager pair
volume.
68792
6005
0
W
Refresh the window, and
confirm whether the status of
the specified volume is
SSWS.
The Reverse Resync operation
failed because the status of
the specified volume was not
SSWS.
68793
6005
0
W
Create a path from the RCU
to the MCU.
The operation failed because
the path from the RCU to the
MCU did not exist.
68794
6005
0
E
Contact HP technical support,
and check the shared
memory.
The operation failed. The
shared memory might be
insufficient.
Call HP technical support.
68795
6005