background image

 

 

OneWireless Adapter 

Honeywell Documentation 

Rev A2 

2 November 2010

 

Professional Installation Guide 

XXXXXXXXX 

 

Page 1 of 20

 

 
 

OneWireless Adapter 

Professional Installation Guide 

 
 

Document ID:  XXXXXXXXX 

Document File:  OneWireless Adapter Pro-Install Guide Rev A2 (Preliminary).docx 

Last Revision Date:  2 November 2010 

Version:  Rev A2 

 
 
 
 
 
 

 

 
 
 
 
 
 
 
 

 

 

Summary of Contents for OneWireless Adapter

Page 1: ...r 2010 Professional Installation Guide XXXXXXXXX Page 1 of 20 OneWireless Adapter Professional Installation Guide Document ID XXXXXXXXX Document File OneWireless Adapter Pro Install Guide Rev A2 Preliminary docx Last Revision Date 2 November 2010 Version Rev A2 ...

Page 2: ...pter Honeywell Documentation Rev A2 2 November 2010 Professional Installation Guide XXXXXXXXX Page 2 of 20 Date Revision Reason 24 September 2010 A1 Initial Draft 2 November 2010 A2 Updated Safety Approval Information ...

Page 3: ...Y USAGE 10 6 1 NORTH AMERICA 10 6 2 EUROPEAN UNION 10 7 OWA GENERAL DESCRIPTION 11 7 1 INTENDED USE 11 7 2 OWA DIAGRAMS 11 8 PRODUCT SPECIFICATIONS 11 8 1 ISA100 RADIO 2 4 GHZ 11 8 2 OWA USER ENVIRONMENT 11 8 3 OWA POWER SPECIFICATIONS 12 8 4 WEIGHT 12 8 5 DIMENSIONS 12 9 APPROVED ANTENNA TYPES GAINS 13 10 EQUIVALENT ISOTROPICALLY RADIATED POWER EIRP 13 11 EIRP LIMITS 14 12 SETTING TX POWER 15 13 ...

Page 4: ...al Installation Guide XXXXXXXXX Page 4 of 20 15 2 PRODUCT SAFETY AGENCY CERTIFICATIONS 17 15 2 1 Canadian Standards Association CSA 17 15 2 2 Factory Mutual FM 17 15 2 3 European ATEX Certification ATEX 19 15 2 4 European Union Certification CE mark 19 16 REFERENCE DOCUMENTS 20 ...

Page 5: ...___________________________________ 12 LIST OF TABLES Table 1 Table of Abbreviations and Definitions 7 Table 2 Specifications of ISA100 Radio Module in OWA 11 Table 3 User Environment Specifications for OWA 11 Table 4 Approved Antenna Types Gains 13 Table 5 Maximum EIRP Limits for ISA100 Radios 14 Table 6 Factory Transmit Power Settings for FCC IC and ETSI 14 Table 7 Reference documents 20 ...

Page 6: ...OWA is intended to be directly connected to a HART device or network and provide a wireless interface between the wired HART network and the wireless ISA100 network 1 2 Scope This document outlines professional installation requirements for the Honeywell OWA Professional installation is required to comply with certification agency and legal requirements This document must be adhered to for all ins...

Page 7: ...d all subassemblies housed within the OWA enclosure Table 1 Table of Abbreviations and Definitions ACMA Australian Communications and Media Authority AD Authentication Device ATEX Potentially Explosive Atmospheres Directive AWG American Wire Gauge Co located Two or more radios transmitting simultaneously and with less than 20 cm of separation distance CSA Canadian Standards Association DCS Distrib...

Page 8: ... at his own expense Intentional or unintentional changes or modifications must not be made to the OWA unless under the express consent of the party responsible for compliance Any such modifications could void the user s authority to operate the equipment and will void the manufacturer s warranty 3 INDUSTRY CANADA IC 3 1 IC Compliance Statements To reduce potential radio interference to other users...

Page 9: ...on is shown on the label attached to each RF Module Honeywell OWA Radio Module Identification o Honeywell Identification for Intrinsically Safe RF Modules 50025034 002 Honeywell OWA Radio Limited Modular Approval o Federal Communication Commission Identification for Intrinsically Safe RF Modules S5750025034 o Industry Canada Identification for Intrinsically Safe RF Modules 573I 50025034 ...

Page 10: ... EUROPEAN UNION Country ISO 3166 2 letter code Country ISO 3166 2 letter code Austria AT Latvia LV Belgium BE Liechtenstein LI Bulgaria BG Lithuania LT Cyprus CY Malta MT Czech Republic CZ Netherlands NL Denmark DK Norway NO Estonia EE Poland PL Finland FI Portugal PT France FR Romania RO Germany DE Slovakia SK Greece GR Slovenia SI Hungary HU Spain ES Iceland IS Sweden SE Ireland IE Switzerland C...

Page 11: ...s document See Section 10 for professional installation maximum TX power setting requirements Only the specified TX power settings and antenna as outlined in this document are valid for OWA installations Table 2 Specifications of ISA100 Radio Module in OWA 8 2 OWA User Environment Table 3 User Environment Specifications for OWA Item Specification Operating Temperature 40ºC to 85ºC 40 F to 185 F St...

Page 12: ...XXXXXX Page 12 of 20 8 3 OWA Power Specifications The OWA operates from one a D size 3 6V Lithium Thionyl Chloride Li SOCl2 battery and from power scavenging from the 4 20mA loop to which it is attached 8 4 Weight The weight of the complete OWA unit is 1 lb 0 45 kg 8 5 Dimensions Figure 1 OWA Dimensions ...

Page 13: ...power that would have to be emitted by an isotropic antenna that evenly distributes power in all directions and is a theoretical construct to produce the peak power density observed in the direction of maximum antenna gain EIRP can take into account the losses in transmission line and connectors and includes the gain of the antenna The EIRP is often stated in terms of decibels over a reference pow...

Page 14: ...s shown above shall not be exceeded 4 Industry Canada Compliance Statement This device has been designed to operate with the antenna types listed in this document Antenna types not included in this list are strictly prohibited for use with this device Table 6 Factory Transmit Power Settings for FCC IC and ETSI Description TX Power Setting for ETSI 3 dBm TX Power Setting for FCC IC 3 dBm 2 5 dBi In...

Page 15: ...ed to be Honeywell sensitive material and is made available only to the qualified Professional Installer Due to radio approval body regulations changing the TX Power setting is only available if the professional installer option has been explicitly enabled on your Authentication Device If you do not have the professional installer option enabled and would like to do so then please contact Honeywel...

Page 16: ...ure requirements the following antenna installation and device operating configurations must be satisfied The OWA unit must not be co located with any other antenna or transmitter device and have a separation distance of at least 20 cm from all persons THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1 THIS DEVICE MAY NOT CAUSE HARMFUL INTERFE...

Page 17: ...ory Use Part 1 General Requirements C22 2 No 0 General Requirements Canadian Electrical Code Part II C22 2 No 94 Special Purpose Enclosures Industrial Products C22 2 No 142 Industrial Control Equipment Industrial Products C22 2 No 157 Intrinsically Safe and Non Incendive Equipment for Use in Hazardous Locations C22 2 No 213 Non Incendive Electrical Equipment for Use in Class I Division 2 Hazardous...

Page 18: ...r Electrical Equipment 1 000 Volts Maximum ANSI ISA 12 00 01 2002 IEC 60079 0 Mod Electrical Apparatus for Explosive Gas Atmospheres General Requirements ANSI ISA 12 02 01 2002 IEC 60079 11 Mod Electrical Apparatus for Explosive Gas Atmospheres Intrinsic Safety ANSI IEC 60529 Degrees of protection provided by enclosures IP Code ANSI ISA 60079 31 12 10 03 Explosive Atmospheres Part 31 Equipment Dus...

Page 19: ...ature code for the OWA shall not exceed T4 135 C based on the maximum specified ambient of 85 C 15 2 4 IECEx Certification IEC 60079 0 Electrical Apparatus for Explosive Gas Atmospheres Part 0 General Requirements IEC 60079 11 Electrical Apparatus for Explosive Gas Atmospheres Part 11 Intrinsic Safety i IEC 60079 15 Electrical Apparatus for Explosive Gas Atmospheres Part 15 Electrical Apparatus wi...

Page 20: ...ywell OneWireless 2 Honeywell OneWireless Planning Guide 3 OneWireless OWA Model Selection Guides 4 Honeywell OWA User s Manuals 5 Honeywell OneWireless System Administration Guide 6 Honeywell OneWireless Field Network Dictionary 7 OneWireless Builder Parameter Reference 8 OneWireless Builder User s Guide These reference documents may be found on the Honeywell HPS website for Wireless Instrumentat...