76
Array Design Considerations
another, two or one disk enclosures, respectively, can be added by using split-bus mode.
However, if you are adding up to four, five, or six enclosure, the enclosures configuration
will need to be switched from split-bus to full-bus (refer to “Disk Enclosure Bus
Configuration” section, earlier in this chapter, for additional information).
Note
Typically adding only one enclosure does not provide any options for creating
LUNs. It is best to expand the array with at least a minimum of two disk
enclosures at a time. Two additional drives could then be configured as RAID 1
or 0/1.
Installing a five disk enclosure array limits expansion to six disk enclosures.
Adding one additional enclosure does not provide any versatility for creating
LUNs (unless all data is removed and the LUNs are rebuilt).
If the initial installation uses split-bus disk enclosure (split-bus accepts three disk
enclosures maximum) and expansion requires adding four or more enclosures, the existing
disk enclosures will need to be reconfigured for full-bus mode and the additional number
of enclosures installed into the rack and required number of full-bus enclosures. This
expansion requires disk enclosures be recabled using full bus enclosures. As in all cases of
adding disk enclosures to the array, the system has to be shut down for the expansion.
Determine the RAID level and how the LUNs will be created for the expansion
If the initial installation consisted of one or more full-bus configured disk enclosures, then
additional full-bus configured disk enclosures can be added to the array. The system should
be shut down for the addition of the enclosures. Determine the RAID level and how the
LUNs will be created for the additional storage.
To scale up sequential performance, first make sure that the configuration includes both
controllers modules. Maximum sequential transfer performance will be reached with
approximately 20 disk modules simultaneously transferring data. To achieve additional
sequential transfer performance, you will need to add a second disk array and more disk
modules.
To increase I/Os per second performance, add disk modules. Transaction performance is
directly related to the number of disk modules installed in the disk array.
Summary of Contents for Surestore Disk Array 12h - And FC60
Page 16: ...16 ...
Page 36: ...36 Array Controller Enclosure Components Figure 9 Controller Enclosure Front View ...
Page 41: ...Array Controller Enclosure Components 41 Product Description Figure 13 Controller Fan Module ...
Page 44: ...44 Array Controller Enclosure Components Figure 15 Power Supply Fan Module ...
Page 68: ...68 Capacity Management Features ...
Page 117: ...Topologies for HP UX 117 Topology and Array Planning Figure 39 High Availability Topology ...
Page 122: ...122 Topologies for HP UX Figure 40 High Availability Distance and Capacity Topology ...
Page 126: ...126 Topologies for HP UX Figure 41 Campus Topology ...
Page 130: ...130 Topologies for HP UX Figure 43 Four Hosts Connected to Cascaded Switches ...
Page 142: ...142 Topologies for Windows NT and Windows 2000 ...
Page 158: ...158 Installing the Disk Array FC60 Figure 54 Enclosure EIA Positions for System E Racks ...
Page 161: ...Installing the Disk Enclosures 161 Installation Figure 56 Disk Enclosure Contents ...
Page 172: ...172 Installing the Controller Figure 62 Controller Enclosure Package Contents ...
Page 174: ...174 Installing the Controller Figure 63 Mounting the Controller Enclosure ...
Page 234: ...234 Adding Disk Enclosures to Increase Capacity ...
Page 274: ...274 Managing the Disk Array Using SAM Unassigned disks selected as hot spares ...
Page 345: ...HP UX Diagnostic Tools 345 5 HP UX DIAGNOSTIC TOOLS Overview 346 Support Tools Manager 347 ...
Page 350: ...350 Support Tools Manager Figure 90 mstm Interface Main Window ...
Page 358: ...358 Support Tools Manager ...
Page 440: ...440 FCC Statements USA Only ...
Page 466: ...466 Index ...