Attaching SCSI Cables and Configuring the Disk Enclosure Switches
191
Inst
alla
tion
Split-Bus Switch and Cabling Configurations
Split-bus cabling requires two SCSI cables from each disk enclosure to the controller
enclosure. Split-bus cabling is typically used for installations with 3 or fewer disk
enclosures. Cabling for a split-bus configuration is shown in
Figure 71
.
Note
For consistency and ease of managment, it is recommended that you observe
the following rules:
- Connect channels 1 and 2 on the controller enclosure to the disk enclosure
mounted directly beneath the controller enclosure. Connect channels 3 and 4 to
the next disk enclosure down, and channels 5 and 6 to the next enclosure down.
- Install cables along the left side of the disk enclosure connectors (as viewed
from the back of the rack) and install terminators along the right side
connectors.
To configure the disk array for split-bus operation:
1. Connect one end of a SCSI cable to the controller enclosure SCSI channel 1 connector,
J12 JVD ARRAY SCSI 1 (see
Figure 71
).
2. Connect the other end of the SCSI cable to the disk enclosure BCC A, SCSI connector B.
3. Connect a second SCSI cable to the controller enclosure SCSI channel 2 connector, J11
JVD ARRAY SCSI 2.
4. Connect the other end of the SCSI cable to the disk enclosure BCC B, SCSI connector A .
Note
The lower BCC is inverted from the upper BCC. Make sure you take this into
account when setting the switches.
5. Set the Enclosure (Tray) ID rotary switches on both BCCs to “0”. See
Figure 70
.
6. Set all segments of the Enclosure DIP switches on both BCCs to “0”.
7. Connect a SCSI terminator to the remaining SCSI connector on each BCC.
8. Repeat the preceding steps for the remaining disk enclosures, using the next sequential
SCSI channels and incrementing the Disk Enclosure (Tray) ID setting for each
enclosure.
Summary of Contents for Surestore Disk Array 12h - And FC60
Page 16: ...16 ...
Page 36: ...36 Array Controller Enclosure Components Figure 9 Controller Enclosure Front View ...
Page 41: ...Array Controller Enclosure Components 41 Product Description Figure 13 Controller Fan Module ...
Page 44: ...44 Array Controller Enclosure Components Figure 15 Power Supply Fan Module ...
Page 68: ...68 Capacity Management Features ...
Page 117: ...Topologies for HP UX 117 Topology and Array Planning Figure 39 High Availability Topology ...
Page 122: ...122 Topologies for HP UX Figure 40 High Availability Distance and Capacity Topology ...
Page 126: ...126 Topologies for HP UX Figure 41 Campus Topology ...
Page 130: ...130 Topologies for HP UX Figure 43 Four Hosts Connected to Cascaded Switches ...
Page 142: ...142 Topologies for Windows NT and Windows 2000 ...
Page 158: ...158 Installing the Disk Array FC60 Figure 54 Enclosure EIA Positions for System E Racks ...
Page 161: ...Installing the Disk Enclosures 161 Installation Figure 56 Disk Enclosure Contents ...
Page 172: ...172 Installing the Controller Figure 62 Controller Enclosure Package Contents ...
Page 174: ...174 Installing the Controller Figure 63 Mounting the Controller Enclosure ...
Page 234: ...234 Adding Disk Enclosures to Increase Capacity ...
Page 274: ...274 Managing the Disk Array Using SAM Unassigned disks selected as hot spares ...
Page 345: ...HP UX Diagnostic Tools 345 5 HP UX DIAGNOSTIC TOOLS Overview 346 Support Tools Manager 347 ...
Page 350: ...350 Support Tools Manager Figure 90 mstm Interface Main Window ...
Page 358: ...358 Support Tools Manager ...
Page 440: ...440 FCC Statements USA Only ...
Page 466: ...466 Index ...