Array Design Considerations
71
T
opo
logy
and
Ar
ra
y
Pla
nnin
g
Array Design Considerations
The Disk Array FC60 provides the versatility to meet varying application storage needs. To
meet a specific application need, the array should be configured to optimize the features
most important for the application. Array features include:
•
High availability
•
Performance (high I/O transfer rates)
•
Storage capacity (optimize for lowest cost/Mbyte)
•
Scalability
Optimizing array operation for a specific feature is managed by configuring various array
installation and operation options. These options include: hardware configuration, RAID
level and LUN creation, the number of SC10 disk enclosures used, and system support
software. It should be noted that optimizing the disk array for one feature may compromise
another. For example, optimizing for maximum performance may increase the cost per
megabyte of storeage.
Array Hardware Configuration
Array configuration options that affect high availability, performance, and storage capacity
include Fibre Channel connections, disk enclosure bus configuration, and internal Ultra2
SCSI channels. This information is presented first, because it is the basis for some of the
array configuration planning.
Fibre Channel Connection
If the controller enclosure has both controller modules installed, dual Fibre Channels can
be connected to the controller enclosure (if only one controller module is installed, only
one Fibre Channel cable can be connected). Using dual Fibre Channel-AL connections
increases the data throughput and provides for higher data availability.
Ultra2 SCSI Channel Operations
The disk array controller enclosure provides six Ultra2 SCSI channel connections for up to
six disk enclosures. Six separate SCSI channels provide configuration flexibility. Disk
Summary of Contents for Surestore Disk Array 12h - And FC60
Page 16: ...16 ...
Page 36: ...36 Array Controller Enclosure Components Figure 9 Controller Enclosure Front View ...
Page 41: ...Array Controller Enclosure Components 41 Product Description Figure 13 Controller Fan Module ...
Page 44: ...44 Array Controller Enclosure Components Figure 15 Power Supply Fan Module ...
Page 68: ...68 Capacity Management Features ...
Page 117: ...Topologies for HP UX 117 Topology and Array Planning Figure 39 High Availability Topology ...
Page 122: ...122 Topologies for HP UX Figure 40 High Availability Distance and Capacity Topology ...
Page 126: ...126 Topologies for HP UX Figure 41 Campus Topology ...
Page 130: ...130 Topologies for HP UX Figure 43 Four Hosts Connected to Cascaded Switches ...
Page 142: ...142 Topologies for Windows NT and Windows 2000 ...
Page 158: ...158 Installing the Disk Array FC60 Figure 54 Enclosure EIA Positions for System E Racks ...
Page 161: ...Installing the Disk Enclosures 161 Installation Figure 56 Disk Enclosure Contents ...
Page 172: ...172 Installing the Controller Figure 62 Controller Enclosure Package Contents ...
Page 174: ...174 Installing the Controller Figure 63 Mounting the Controller Enclosure ...
Page 234: ...234 Adding Disk Enclosures to Increase Capacity ...
Page 274: ...274 Managing the Disk Array Using SAM Unassigned disks selected as hot spares ...
Page 345: ...HP UX Diagnostic Tools 345 5 HP UX DIAGNOSTIC TOOLS Overview 346 Support Tools Manager 347 ...
Page 350: ...350 Support Tools Manager Figure 90 mstm Interface Main Window ...
Page 358: ...358 Support Tools Manager ...
Page 440: ...440 FCC Statements USA Only ...
Page 466: ...466 Index ...