
454
drivers on the bus, and also impedance matching to prevent signal reflections at the
ends of the cable. The SCSI bus requires termination at both ends of the bus. One end of
the SCSI bus is terminated by the adapter’s internal termination. The other end should
have a terminator placed on the 68-pin high density SCSI connector on the last SCSI
peripheral. If this device is not terminated, data errors may occur.
topology
The physical layout of devices on a network. The three Fibre Channel topologies are
fabric, arbitrated loop, and point-to-point. The disk array’s default topology is arbitrated
loop.
unbind
Unbinding reverses the LUN binding process, deleting the LUN and returning the disk
in the LUN to the unassigned disk group. Unbinding destroys all data on the LUN.
Uninterruptible Power Supply (UPS)
An Uninterruptible Power Supply is a power supply that is capable of maintaining
power even if the input ac mains supply loses its source of power.
Universal Transport Mechanism (UTM)
A special LUN reserved for communication between the host and the disk array. SCSI
commands are passed through the UTM. By default LUN 31 is used for the UTM. If the
UTM is disabled, LUN 0 is used for the SCSI command path.
VHDCI
Very high density cable interface.
volume set addressing (VSA)
An enhanced technique for addressing disk array LUNs. VSA overcomes the eight LUN
limit imposed by PDA, allowing all 32 LUNs on the disk array to be addressed by the
host.
Summary of Contents for Surestore Disk Array 12h - And FC60
Page 16: ...16 ...
Page 36: ...36 Array Controller Enclosure Components Figure 9 Controller Enclosure Front View ...
Page 41: ...Array Controller Enclosure Components 41 Product Description Figure 13 Controller Fan Module ...
Page 44: ...44 Array Controller Enclosure Components Figure 15 Power Supply Fan Module ...
Page 68: ...68 Capacity Management Features ...
Page 117: ...Topologies for HP UX 117 Topology and Array Planning Figure 39 High Availability Topology ...
Page 122: ...122 Topologies for HP UX Figure 40 High Availability Distance and Capacity Topology ...
Page 126: ...126 Topologies for HP UX Figure 41 Campus Topology ...
Page 130: ...130 Topologies for HP UX Figure 43 Four Hosts Connected to Cascaded Switches ...
Page 142: ...142 Topologies for Windows NT and Windows 2000 ...
Page 158: ...158 Installing the Disk Array FC60 Figure 54 Enclosure EIA Positions for System E Racks ...
Page 161: ...Installing the Disk Enclosures 161 Installation Figure 56 Disk Enclosure Contents ...
Page 172: ...172 Installing the Controller Figure 62 Controller Enclosure Package Contents ...
Page 174: ...174 Installing the Controller Figure 63 Mounting the Controller Enclosure ...
Page 234: ...234 Adding Disk Enclosures to Increase Capacity ...
Page 274: ...274 Managing the Disk Array Using SAM Unassigned disks selected as hot spares ...
Page 345: ...HP UX Diagnostic Tools 345 5 HP UX DIAGNOSTIC TOOLS Overview 346 Support Tools Manager 347 ...
Page 350: ...350 Support Tools Manager Figure 90 mstm Interface Main Window ...
Page 358: ...358 Support Tools Manager ...
Page 440: ...440 FCC Statements USA Only ...
Page 466: ...466 Index ...