304
Managing the Disk Array Using Array Manager 60
Performing Disk Array Maintenance
At some point during operation of the disk array, you may need to perform maintenance
tasks that involve error recovery and problem isolation. This section describes the tasks
involved in maintaining the disk array.
Locating Disk Modules
Array Manager 60 provides the means of identifying a disk module by flashing its amber
Fault LED. You can flash the Fault LED on an individual disk, or on all the disks in the
array. It is advisable to positively identify a failed disk before removing it from the disk
array. Removing the wrong disk could cause the data on the LUN to become unavailable.
To locate a disk module, type:
amutil <option> <ArrayID>
•
option identifies the disk modules you want to identify.
Table 39
lists valid
options.
Command Example
The following example flashes the Fault LED on disk 3 on channel 2 in disk array
data_center_1:
amutil -f 2:3 data_center_1
Table 39
Command Options for Locating Disk Array Components
Option
Description
-f channel:ID
Flash the
Fault
LED on the specified disk. A disk is identified by both
channel (1- 6) and SCSI ID (0 - 4, 8 - 12).
-F
Flash the
Fault
LEDs on all the disks in the disk array.
-s
Stop flashing the disk
Fault
LEDs. This option works for both a single
disk and multiple disks.
Summary of Contents for Surestore Disk Array 12h - And FC60
Page 16: ...16 ...
Page 36: ...36 Array Controller Enclosure Components Figure 9 Controller Enclosure Front View ...
Page 41: ...Array Controller Enclosure Components 41 Product Description Figure 13 Controller Fan Module ...
Page 44: ...44 Array Controller Enclosure Components Figure 15 Power Supply Fan Module ...
Page 68: ...68 Capacity Management Features ...
Page 117: ...Topologies for HP UX 117 Topology and Array Planning Figure 39 High Availability Topology ...
Page 122: ...122 Topologies for HP UX Figure 40 High Availability Distance and Capacity Topology ...
Page 126: ...126 Topologies for HP UX Figure 41 Campus Topology ...
Page 130: ...130 Topologies for HP UX Figure 43 Four Hosts Connected to Cascaded Switches ...
Page 142: ...142 Topologies for Windows NT and Windows 2000 ...
Page 158: ...158 Installing the Disk Array FC60 Figure 54 Enclosure EIA Positions for System E Racks ...
Page 161: ...Installing the Disk Enclosures 161 Installation Figure 56 Disk Enclosure Contents ...
Page 172: ...172 Installing the Controller Figure 62 Controller Enclosure Package Contents ...
Page 174: ...174 Installing the Controller Figure 63 Mounting the Controller Enclosure ...
Page 234: ...234 Adding Disk Enclosures to Increase Capacity ...
Page 274: ...274 Managing the Disk Array Using SAM Unassigned disks selected as hot spares ...
Page 345: ...HP UX Diagnostic Tools 345 5 HP UX DIAGNOSTIC TOOLS Overview 346 Support Tools Manager 347 ...
Page 350: ...350 Support Tools Manager Figure 90 mstm Interface Main Window ...
Page 358: ...358 Support Tools Manager ...
Page 440: ...440 FCC Statements USA Only ...
Page 466: ...466 Index ...