Status Conditions and Sense Code Information
323
M
a
na
ging
the
Di
sk
Array
on HP-UX
0x08
Disk Enclosure Group - comprises attached disk enclosures. This group
includes the power supplies, environmental monitor, and other
components in the disk enclosure. See
"Disk Enclosure Group FRU
Code Qualifier" on page 326
for information on identifying component
and status.
0x09-0x0F
Reserved
0x10-0xFF
Drive Groups - comprises a drive (embedded controller, drive electronics,
and Head Disk Assembly), its power supply, and the SCSI cable that
connects it to the controller; or supporting sub-enclosure environmental
electronics. The FRU code designates the channel ID in the most
significant nibble and the SCSI ID of the drive in the least significant
nibble.
NOTE: Channel ID 0 is not used because a failure of drive ID 0 on this
channel would cause an FRU code of 0x00, which the SCSI-2 standard
defines as no specific unit has been identified to have failed or that the
data is not available.
Table 43
FRU Code Groups
FRU Code Value
Group Description
Summary of Contents for Surestore Disk Array 12h - And FC60
Page 16: ...16 ...
Page 36: ...36 Array Controller Enclosure Components Figure 9 Controller Enclosure Front View ...
Page 41: ...Array Controller Enclosure Components 41 Product Description Figure 13 Controller Fan Module ...
Page 44: ...44 Array Controller Enclosure Components Figure 15 Power Supply Fan Module ...
Page 68: ...68 Capacity Management Features ...
Page 117: ...Topologies for HP UX 117 Topology and Array Planning Figure 39 High Availability Topology ...
Page 122: ...122 Topologies for HP UX Figure 40 High Availability Distance and Capacity Topology ...
Page 126: ...126 Topologies for HP UX Figure 41 Campus Topology ...
Page 130: ...130 Topologies for HP UX Figure 43 Four Hosts Connected to Cascaded Switches ...
Page 142: ...142 Topologies for Windows NT and Windows 2000 ...
Page 158: ...158 Installing the Disk Array FC60 Figure 54 Enclosure EIA Positions for System E Racks ...
Page 161: ...Installing the Disk Enclosures 161 Installation Figure 56 Disk Enclosure Contents ...
Page 172: ...172 Installing the Controller Figure 62 Controller Enclosure Package Contents ...
Page 174: ...174 Installing the Controller Figure 63 Mounting the Controller Enclosure ...
Page 234: ...234 Adding Disk Enclosures to Increase Capacity ...
Page 274: ...274 Managing the Disk Array Using SAM Unassigned disks selected as hot spares ...
Page 345: ...HP UX Diagnostic Tools 345 5 HP UX DIAGNOSTIC TOOLS Overview 346 Support Tools Manager 347 ...
Page 350: ...350 Support Tools Manager Figure 90 mstm Interface Main Window ...
Page 358: ...358 Support Tools Manager ...
Page 440: ...440 FCC Statements USA Only ...
Page 466: ...466 Index ...