
108
Topologies for HP-UX
Table 8
Basic Topology Error Recovery
Failing
component
Continue
after failure
What happens and how to recover
Disk module
Yes
Applications continue to run on all supported RAID levels (RAID-
1, 0/1, and 5). The system administrator or service provider hot-
swaps the failed disk module.
Controller
module in
single-
controller
module array
(no high
availability)
No
The disk array fails. The system administrator or service provider
replaces the controller module and the system administrator
restarts the operating system and applications.
Controller
module in
dual
controller
module disk
array
No on path to
failed controller
module;
Yes on alternate
path through
second
controller
module
Ownership of the failed controller module’s LUNs can transfer
automatically to the remaining operational controller module if
primary and alternate paths have been configured in LVM. If so,
LVM switches automatically and transparently to the alternate
path. The system administrator or service provider hot-swaps the
controller module.
Fan module
Yes
Applications continue to run. The system administrator or service
provider hot-swaps the fan module.
Power
supply
modules
Yes
Applications continue to run when one power supply module fails.
The system administrator or service provider hot-swaps the failed
power supply module.
Fibre
Channel I/O
adapter
No on path to
failed adapter;
Yes if array has
dual controller
modules and
alternate paths
have been
configured
I/O operations fail along the path through the failed adapter. If the
host has two Fibre Channel adapters connected to a dual
controller module disk array, the array can be accessed through
the path to the operational adapter and controller module if
primary and alternate paths have been configured in LVM. If so,
LVM switches automatically and transparently to the alternate
path. The authorized service provider replaces the failed adapter
and the system administrator restarts the operating system and
applications.
Summary of Contents for Surestore Disk Array 12h - And FC60
Page 16: ...16 ...
Page 36: ...36 Array Controller Enclosure Components Figure 9 Controller Enclosure Front View ...
Page 41: ...Array Controller Enclosure Components 41 Product Description Figure 13 Controller Fan Module ...
Page 44: ...44 Array Controller Enclosure Components Figure 15 Power Supply Fan Module ...
Page 68: ...68 Capacity Management Features ...
Page 117: ...Topologies for HP UX 117 Topology and Array Planning Figure 39 High Availability Topology ...
Page 122: ...122 Topologies for HP UX Figure 40 High Availability Distance and Capacity Topology ...
Page 126: ...126 Topologies for HP UX Figure 41 Campus Topology ...
Page 130: ...130 Topologies for HP UX Figure 43 Four Hosts Connected to Cascaded Switches ...
Page 142: ...142 Topologies for Windows NT and Windows 2000 ...
Page 158: ...158 Installing the Disk Array FC60 Figure 54 Enclosure EIA Positions for System E Racks ...
Page 161: ...Installing the Disk Enclosures 161 Installation Figure 56 Disk Enclosure Contents ...
Page 172: ...172 Installing the Controller Figure 62 Controller Enclosure Package Contents ...
Page 174: ...174 Installing the Controller Figure 63 Mounting the Controller Enclosure ...
Page 234: ...234 Adding Disk Enclosures to Increase Capacity ...
Page 274: ...274 Managing the Disk Array Using SAM Unassigned disks selected as hot spares ...
Page 345: ...HP UX Diagnostic Tools 345 5 HP UX DIAGNOSTIC TOOLS Overview 346 Support Tools Manager 347 ...
Page 350: ...350 Support Tools Manager Figure 90 mstm Interface Main Window ...
Page 358: ...358 Support Tools Manager ...
Page 440: ...440 FCC Statements USA Only ...
Page 466: ...466 Index ...