220
Configuring the Disk Array
•
For more information, see
"Adding a Global Hot Spare" on page 296
•
To use SAM, see
"Adding a Global Hot Spare" on page 273
Step 10. Install Special Device Files
After binding LUNs, you must install special device files on the LUNs. This makes the LUNs
usable by the operating system.
To install the special device files, type:
insf -e
Step 11. Check Disk Array Status
The final step is to display the disk array status to ensure that all features are enabled and
that the array is working properly.
To display disk array status, type:
amdsp -a <ArrayID>
See
Figure 88 on page 284
for a sample status display output that identifies the important
fields and the normal values.
Windows NT and Windows 2000
Perform the following steps to configure the disk for operation on a Windows NT or
Windows 2000 host. Refer to the HP Storage Manager 60 User’s Guide for detailed
instructions on performing each of these tasks.
1. Add the disk array to the SM60 management topology.
2. Set up any alert notifications.
3. Rename the disk array.
4. Create the desired volume structure. Replace the default 10 Mbyte volume if necessary.
5. Add hot spares as required.
Summary of Contents for Surestore Disk Array 12h - And FC60
Page 16: ...16 ...
Page 36: ...36 Array Controller Enclosure Components Figure 9 Controller Enclosure Front View ...
Page 41: ...Array Controller Enclosure Components 41 Product Description Figure 13 Controller Fan Module ...
Page 44: ...44 Array Controller Enclosure Components Figure 15 Power Supply Fan Module ...
Page 68: ...68 Capacity Management Features ...
Page 117: ...Topologies for HP UX 117 Topology and Array Planning Figure 39 High Availability Topology ...
Page 122: ...122 Topologies for HP UX Figure 40 High Availability Distance and Capacity Topology ...
Page 126: ...126 Topologies for HP UX Figure 41 Campus Topology ...
Page 130: ...130 Topologies for HP UX Figure 43 Four Hosts Connected to Cascaded Switches ...
Page 142: ...142 Topologies for Windows NT and Windows 2000 ...
Page 158: ...158 Installing the Disk Array FC60 Figure 54 Enclosure EIA Positions for System E Racks ...
Page 161: ...Installing the Disk Enclosures 161 Installation Figure 56 Disk Enclosure Contents ...
Page 172: ...172 Installing the Controller Figure 62 Controller Enclosure Package Contents ...
Page 174: ...174 Installing the Controller Figure 63 Mounting the Controller Enclosure ...
Page 234: ...234 Adding Disk Enclosures to Increase Capacity ...
Page 274: ...274 Managing the Disk Array Using SAM Unassigned disks selected as hot spares ...
Page 345: ...HP UX Diagnostic Tools 345 5 HP UX DIAGNOSTIC TOOLS Overview 346 Support Tools Manager 347 ...
Page 350: ...350 Support Tools Manager Figure 90 mstm Interface Main Window ...
Page 358: ...358 Support Tools Manager ...
Page 440: ...440 FCC Statements USA Only ...
Page 466: ...466 Index ...