
Disk Array High Availability Features
59
Produ
ct Des
c
ript
ion
Table 4
RAID Level Comparison: General Performance Characteristics
RAID Level
General Performance Characteristics
RAID 0
– Simultaneous access to multiple disks increases I/O performance. In
general, the greater the number of mirrored pairs, the greater the increase
in performance.
RAID 1
– A RAID 1 mirrored pair requires one I/O operation for a read and two I/O
operations for a write, one to each disk in the pair.
– The disks in a RAID 1 mirrored pair are locked in synchronization, but the
disk array can read data from the module whose read/write heads are the
closest.
– RAID 1 read performance can be twice that of an individual disk. Write
performance can be the same as that of an individual disk.
RAID 0/1
– Simultaneous access to multiple mirrored pairs increases I/O performance.
In general, the greater the number of mirrored pairs, the greater the
increase in performance.
RAID 3
– Provides high read throughput for large sequential I/Os.
– Write performance is limited by the need to perform four I/O operations per
write request.
– Because some I/O operations occur simultaneously, performance depends
on the number of disks in the LUN. Additional disks may improve
performance.
– The I/O performance of RAID 5 benefits significantly from write caching.
RAID 5
– Provides high read throughput for small block-size requests (2 KB to 8 KB).
– Write performance is limited by the need to perform four I/O operations per
write request.
– Because some I/O operations occur simultaneously, performance depends
on the number of disks in the LUN. Additional disks may improve
performance.
– The I/O performance of RAID 5 benefits significantly from write caching.
Summary of Contents for Surestore Disk Array 12h - And FC60
Page 16: ...16 ...
Page 36: ...36 Array Controller Enclosure Components Figure 9 Controller Enclosure Front View ...
Page 41: ...Array Controller Enclosure Components 41 Product Description Figure 13 Controller Fan Module ...
Page 44: ...44 Array Controller Enclosure Components Figure 15 Power Supply Fan Module ...
Page 68: ...68 Capacity Management Features ...
Page 117: ...Topologies for HP UX 117 Topology and Array Planning Figure 39 High Availability Topology ...
Page 122: ...122 Topologies for HP UX Figure 40 High Availability Distance and Capacity Topology ...
Page 126: ...126 Topologies for HP UX Figure 41 Campus Topology ...
Page 130: ...130 Topologies for HP UX Figure 43 Four Hosts Connected to Cascaded Switches ...
Page 142: ...142 Topologies for Windows NT and Windows 2000 ...
Page 158: ...158 Installing the Disk Array FC60 Figure 54 Enclosure EIA Positions for System E Racks ...
Page 161: ...Installing the Disk Enclosures 161 Installation Figure 56 Disk Enclosure Contents ...
Page 172: ...172 Installing the Controller Figure 62 Controller Enclosure Package Contents ...
Page 174: ...174 Installing the Controller Figure 63 Mounting the Controller Enclosure ...
Page 234: ...234 Adding Disk Enclosures to Increase Capacity ...
Page 274: ...274 Managing the Disk Array Using SAM Unassigned disks selected as hot spares ...
Page 345: ...HP UX Diagnostic Tools 345 5 HP UX DIAGNOSTIC TOOLS Overview 346 Support Tools Manager 347 ...
Page 350: ...350 Support Tools Manager Figure 90 mstm Interface Main Window ...
Page 358: ...358 Support Tools Manager ...
Page 440: ...440 FCC Statements USA Only ...
Page 466: ...466 Index ...