330
Status Conditions and Sense Code Information
21
00
Logical Block Address Out of Range
The controller received a command that requested an operation
at a logical block address beyond the capacity of the logical
unit. This error could be in response to a request with an illegal
starting address or a request that started at a valid logical block
address and the number of blocks requested extended beyond
the logical unit capacity.
24
00
Invalid Field in CDB
The controller received a command from the initiator with an
unsupported value in one of the fields in the command block.
25
00
Logical Unit Not Supported
The addressed logical unit is currently unconfigured. An Add
LUN operation in the Logical Array Mode Page must be exe-
cuted to define the logical unit before it is accessible.
26
00
Invalid Field in Parameter List
The controller received a command with a parameter list that
contained an error. Typical errors that return this code are
unsupported mode pages, attempts to change an unchange-
able mode parameter, or attempts to set a changeable mode
parameter to an unsupported value.
28
00
Not Ready to Ready Transition
The controller has completed its initialization operations on the
logical unit and it is now ready for access.
29
00
Power On, Reset, or Bus Device Reset Occurred
The controller has detected one of the above conditions.
Table 44
SCSI Sense Codes (cont’d)
Additional
Sense
Code
Additional
Sense Code
Qualifier
Interpretation
Summary of Contents for Surestore Disk Array 12h - And FC60
Page 16: ...16 ...
Page 36: ...36 Array Controller Enclosure Components Figure 9 Controller Enclosure Front View ...
Page 41: ...Array Controller Enclosure Components 41 Product Description Figure 13 Controller Fan Module ...
Page 44: ...44 Array Controller Enclosure Components Figure 15 Power Supply Fan Module ...
Page 68: ...68 Capacity Management Features ...
Page 117: ...Topologies for HP UX 117 Topology and Array Planning Figure 39 High Availability Topology ...
Page 122: ...122 Topologies for HP UX Figure 40 High Availability Distance and Capacity Topology ...
Page 126: ...126 Topologies for HP UX Figure 41 Campus Topology ...
Page 130: ...130 Topologies for HP UX Figure 43 Four Hosts Connected to Cascaded Switches ...
Page 142: ...142 Topologies for Windows NT and Windows 2000 ...
Page 158: ...158 Installing the Disk Array FC60 Figure 54 Enclosure EIA Positions for System E Racks ...
Page 161: ...Installing the Disk Enclosures 161 Installation Figure 56 Disk Enclosure Contents ...
Page 172: ...172 Installing the Controller Figure 62 Controller Enclosure Package Contents ...
Page 174: ...174 Installing the Controller Figure 63 Mounting the Controller Enclosure ...
Page 234: ...234 Adding Disk Enclosures to Increase Capacity ...
Page 274: ...274 Managing the Disk Array Using SAM Unassigned disks selected as hot spares ...
Page 345: ...HP UX Diagnostic Tools 345 5 HP UX DIAGNOSTIC TOOLS Overview 346 Support Tools Manager 347 ...
Page 350: ...350 Support Tools Manager Figure 90 mstm Interface Main Window ...
Page 358: ...358 Support Tools Manager ...
Page 440: ...440 FCC Statements USA Only ...
Page 466: ...466 Index ...