366
Power-Up Troubleshooting
Power-Up Troubleshooting
When the disk array is powered up, each component perform an internal self-test, to ensure
it is operating properly.
Visual indications of power-up are:
•
The green Power LED on the controller enclosure is on
•
The green Power LED on each disk enclosures is on
•
All fans are operating
•
No Fault LEDs are on. See
Figure 92 on page 368
and
Figure 93 on page 377
.
The following LEDs will also be on:
•
Controller enclosure:
– The green Full Charge LEDs on the controller batteries, if the batteries are fully
charged. If the batteries are not fully charged, the Full Charge LEDs will flash until
charging is complete, and then remain on.
– The Power LEDs on the controller enclosure
•
Disk enclosure
– The green Power Supply LEDs
– Fan LEDs
If the power-up sequence fails, the appropriate amber Fault LED will be on, identifying the
failing component. If the power-up tests fail, all modules in the disk array must be
examined for Fault LEDs that are on. See
Table 48 on page 369
and
Table 50 on page 377
).
Note
Inserting a module while the power-up tests are running can cause the tests to
fail. Insert all modules and then cycle power to rerun the power-up tests.
Summary of Contents for Surestore Disk Array 12h - And FC60
Page 16: ...16 ...
Page 36: ...36 Array Controller Enclosure Components Figure 9 Controller Enclosure Front View ...
Page 41: ...Array Controller Enclosure Components 41 Product Description Figure 13 Controller Fan Module ...
Page 44: ...44 Array Controller Enclosure Components Figure 15 Power Supply Fan Module ...
Page 68: ...68 Capacity Management Features ...
Page 117: ...Topologies for HP UX 117 Topology and Array Planning Figure 39 High Availability Topology ...
Page 122: ...122 Topologies for HP UX Figure 40 High Availability Distance and Capacity Topology ...
Page 126: ...126 Topologies for HP UX Figure 41 Campus Topology ...
Page 130: ...130 Topologies for HP UX Figure 43 Four Hosts Connected to Cascaded Switches ...
Page 142: ...142 Topologies for Windows NT and Windows 2000 ...
Page 158: ...158 Installing the Disk Array FC60 Figure 54 Enclosure EIA Positions for System E Racks ...
Page 161: ...Installing the Disk Enclosures 161 Installation Figure 56 Disk Enclosure Contents ...
Page 172: ...172 Installing the Controller Figure 62 Controller Enclosure Package Contents ...
Page 174: ...174 Installing the Controller Figure 63 Mounting the Controller Enclosure ...
Page 234: ...234 Adding Disk Enclosures to Increase Capacity ...
Page 274: ...274 Managing the Disk Array Using SAM Unassigned disks selected as hot spares ...
Page 345: ...HP UX Diagnostic Tools 345 5 HP UX DIAGNOSTIC TOOLS Overview 346 Support Tools Manager 347 ...
Page 350: ...350 Support Tools Manager Figure 90 mstm Interface Main Window ...
Page 358: ...358 Support Tools Manager ...
Page 440: ...440 FCC Statements USA Only ...
Page 466: ...466 Index ...