Managing the Disk Array Using Array Manager 60
277
M
a
na
ging
the
Di
sk
Array
on HP-UX
Disk Array Configuration
Assigning an Alias to the Disk
Array
ammgr -D <ArrayAlias> <ArrayID>
Setting Cache Page Size
ammgr -p {4 | 16} <ArrayID>
Setting the Cache Flush
Threshold
ammgr -T <cntrlrID>:<percent> <ArrayID>
Setting the Cache Flush Limit
ammgr -L <cntrlrID>:<percent> <ArrayID>
Disabling Disk Module Write
Cache Enable (WCE)
amutil -w <ArrayID>
Synchronizing the Controller Date
and Time
ammgr -t <ArrayID>
Managing the Universal Transport
Mechanism (UTM)
ammgr -u|-U [-l <LUN>] <ArrayID>
Disk Array Maintenance
Locating Disk Modules
amutil <option> <ArrayID>
Checking Rebuild Progress
amdsp -r <ArrayID>
Changing Rebuild Priority
Settings
amutil -R <LUN> -f <Freq> -a <Amt> <ArrayID>
Performing a Parity Scan
ammgr -P <LUN>
Viewing Disk Array Logs
amlog [-s <StartTime>] [-e <EndTime>] [-d <LogDir>]
[-a <ArrayID>]
Flushing Disk Array Log Contents
amutil -l <ArrayID>
Purging Controller Logs
amutil -p <ArrayID>
Resetting Battery Age
ammgr -b
Table 33
Array Manager 60 Task Summary (cont’d)
Task Command
Summary of Contents for Surestore Disk Array 12h - And FC60
Page 16: ...16 ...
Page 36: ...36 Array Controller Enclosure Components Figure 9 Controller Enclosure Front View ...
Page 41: ...Array Controller Enclosure Components 41 Product Description Figure 13 Controller Fan Module ...
Page 44: ...44 Array Controller Enclosure Components Figure 15 Power Supply Fan Module ...
Page 68: ...68 Capacity Management Features ...
Page 117: ...Topologies for HP UX 117 Topology and Array Planning Figure 39 High Availability Topology ...
Page 122: ...122 Topologies for HP UX Figure 40 High Availability Distance and Capacity Topology ...
Page 126: ...126 Topologies for HP UX Figure 41 Campus Topology ...
Page 130: ...130 Topologies for HP UX Figure 43 Four Hosts Connected to Cascaded Switches ...
Page 142: ...142 Topologies for Windows NT and Windows 2000 ...
Page 158: ...158 Installing the Disk Array FC60 Figure 54 Enclosure EIA Positions for System E Racks ...
Page 161: ...Installing the Disk Enclosures 161 Installation Figure 56 Disk Enclosure Contents ...
Page 172: ...172 Installing the Controller Figure 62 Controller Enclosure Package Contents ...
Page 174: ...174 Installing the Controller Figure 63 Mounting the Controller Enclosure ...
Page 234: ...234 Adding Disk Enclosures to Increase Capacity ...
Page 274: ...274 Managing the Disk Array Using SAM Unassigned disks selected as hot spares ...
Page 345: ...HP UX Diagnostic Tools 345 5 HP UX DIAGNOSTIC TOOLS Overview 346 Support Tools Manager 347 ...
Page 350: ...350 Support Tools Manager Figure 90 mstm Interface Main Window ...
Page 358: ...358 Support Tools Manager ...
Page 440: ...440 FCC Statements USA Only ...
Page 466: ...466 Index ...