Status Conditions and Sense Code Information
335
M
a
na
ging
the
Di
sk
Array
on HP-UX
3F
D0
Write Back Cache Battery Has Been Discharged
The controller’s battery management has indicated that the
cache battery has been discharged.
3F
D1
Write Back Cache Battery Charge Has Completed
The controller’s battery management has indicated that the
cache battery is operational.
3F
D8
Cache Battery Life Expiration
The cache battery has reached the specified expiration age.
3F
D9
Cache Battery Life Expiration Warning
The cache battery is within the specified number of weeks of
failing.
3F
E0
Logical Unit Failure
The controller has placed the logical unit in a "dead" state. User
data and/ or parity can no longer be maintained to ensure avail-
ability. The most likely cause is the failure of a single drive in
non-redundant configurations or a second drive in a configura-
tion protected by one drive. The data on the logical unit is no
longer accessible.
3F
EB
LUN marked DEAD due to Media Error Failure during SOD
An error has occurred during interrupted write processing caus-
ing the LUN to transition to the DEAD state
Table 44
SCSI Sense Codes (cont’d)
Additional
Sense
Code
Additional
Sense Code
Qualifier
Interpretation
Summary of Contents for Surestore Disk Array 12h - And FC60
Page 16: ...16 ...
Page 36: ...36 Array Controller Enclosure Components Figure 9 Controller Enclosure Front View ...
Page 41: ...Array Controller Enclosure Components 41 Product Description Figure 13 Controller Fan Module ...
Page 44: ...44 Array Controller Enclosure Components Figure 15 Power Supply Fan Module ...
Page 68: ...68 Capacity Management Features ...
Page 117: ...Topologies for HP UX 117 Topology and Array Planning Figure 39 High Availability Topology ...
Page 122: ...122 Topologies for HP UX Figure 40 High Availability Distance and Capacity Topology ...
Page 126: ...126 Topologies for HP UX Figure 41 Campus Topology ...
Page 130: ...130 Topologies for HP UX Figure 43 Four Hosts Connected to Cascaded Switches ...
Page 142: ...142 Topologies for Windows NT and Windows 2000 ...
Page 158: ...158 Installing the Disk Array FC60 Figure 54 Enclosure EIA Positions for System E Racks ...
Page 161: ...Installing the Disk Enclosures 161 Installation Figure 56 Disk Enclosure Contents ...
Page 172: ...172 Installing the Controller Figure 62 Controller Enclosure Package Contents ...
Page 174: ...174 Installing the Controller Figure 63 Mounting the Controller Enclosure ...
Page 234: ...234 Adding Disk Enclosures to Increase Capacity ...
Page 274: ...274 Managing the Disk Array Using SAM Unassigned disks selected as hot spares ...
Page 345: ...HP UX Diagnostic Tools 345 5 HP UX DIAGNOSTIC TOOLS Overview 346 Support Tools Manager 347 ...
Page 350: ...350 Support Tools Manager Figure 90 mstm Interface Main Window ...
Page 358: ...358 Support Tools Manager ...
Page 440: ...440 FCC Statements USA Only ...
Page 466: ...466 Index ...