Status Conditions and Sense Code Information
0C
00
If the accompanying sense key = 4, error is interrupted as
follows:
Unrecovered Write Error
Data could not be written to media due to an unrecoverable
RAM, battery or drive error.
If the accompanying sense key = 6, error is interrupted as
follows:
Caching Disabled
Data caching has been disabled due to loss of mirroring capa-
bility or low battery capacity.
0C
01
Write Error Recovered with Auto Reallocation
The controller recovered a write operation to a drive and no fur-
ther action is required by the host. Auto reallocation may not
have been used, but this is the only standard ASC/ ASCQ that
tells the initiator that no further actions are required by the
driver.
0C
80
Unrecovered Write Error Due to Non-Volatile Cache Failure
The subsystem Non-Volatile cache memory recovery mecha-
nisms failed after a power cycle or reset. This is possibly due to
some combination of battery failure, alternate controller failure
or foreign controller.
User data may have been lost.
0C
81
Deferred Unrecoverable Error Due to Memory Failure
Recovery from a Data Cache error was unsuccessful.
User data may have been lost.
Table 44
SCSI Sense Codes (cont’d)
Additional
Sense
Code
Additional
Sense Code
Qualifier
Interpretation
Summary of Contents for Surestore Disk Array 12h - And FC60
Page 16: ...16 ...
Page 36: ...36 Array Controller Enclosure Components Figure 9 Controller Enclosure Front View ...
Page 41: ...Array Controller Enclosure Components 41 Product Description Figure 13 Controller Fan Module ...
Page 44: ...44 Array Controller Enclosure Components Figure 15 Power Supply Fan Module ...
Page 68: ...68 Capacity Management Features ...
Page 117: ...Topologies for HP UX 117 Topology and Array Planning Figure 39 High Availability Topology ...
Page 122: ...122 Topologies for HP UX Figure 40 High Availability Distance and Capacity Topology ...
Page 126: ...126 Topologies for HP UX Figure 41 Campus Topology ...
Page 130: ...130 Topologies for HP UX Figure 43 Four Hosts Connected to Cascaded Switches ...
Page 142: ...142 Topologies for Windows NT and Windows 2000 ...
Page 158: ...158 Installing the Disk Array FC60 Figure 54 Enclosure EIA Positions for System E Racks ...
Page 161: ...Installing the Disk Enclosures 161 Installation Figure 56 Disk Enclosure Contents ...
Page 172: ...172 Installing the Controller Figure 62 Controller Enclosure Package Contents ...
Page 174: ...174 Installing the Controller Figure 63 Mounting the Controller Enclosure ...
Page 234: ...234 Adding Disk Enclosures to Increase Capacity ...
Page 274: ...274 Managing the Disk Array Using SAM Unassigned disks selected as hot spares ...
Page 345: ...HP UX Diagnostic Tools 345 5 HP UX DIAGNOSTIC TOOLS Overview 346 Support Tools Manager 347 ...
Page 350: ...350 Support Tools Manager Figure 90 mstm Interface Main Window ...
Page 358: ...358 Support Tools Manager ...
Page 440: ...440 FCC Statements USA Only ...
Page 466: ...466 Index ...