85
7.3 Servo stop
7. 3. 1 Servo ON
→
OFF
(
motor stops
)
When servo OFF, the deceleration stop release condition is to reach the speed release, or after specified running
time(Parameter No.224.0=1, initial setting) , the motor speed is below the servo OFF deceleration stop release speed
(Parameter No.227.0=50rpm, initial setting).
Figure 7.3.1 Servo ON
→
OFF (motor stops)
Note 1) About I/O status, “C” indicates the internal output circuit contact and external contact is close, while “O” means open.
Note 2) T1 can be set in parameter No.237.0 (initial setting 0msec, changeable range: 0 to 500msec).
7.3.2 Servo ON
→
OFF(motor rotates)
When servo OFF, the deceleration stop release condition is to reach the speed release, or after specified running time
(Parameter No.224.0=1, preferences) but motor speed is above the servo OFF deceleration stop release speed r (Parameter
No.227.0=50rpm, preferences).
Figure 7.3.2 Servo ON
→
OFF(motor rotates)