56
The motor rotates when pressing the button, and stops as releasing the button.
7. Make the servo OFF by I/O and
shows to end the JOG operation. Then press MODE
button and show
, which means the operation status changes from JOG to the general. If the servo is ON, the operation cannot
change from JOG operation to general operation status and the alarm
will occur.
Note 1) Please note that if the JOG operation deceleration time is set longer, the time from pressing the UP
or Down
button to stopping the motor will become longer correspondingly.
Note 2) If press the UP
or Down
button simultaneously, the motor will stop. If the unexpected operating status
happens, switch off the main circuit power or make the servo OFF to stop the operation.
Figure 5.9.2
5.9.2 Parameter clearing function
This function is to return the parameters to the factory settings. After clearing the parameters, restart the power supply and the
parameters will change to the factory settings.
The parameter clearing should be operated at the servo OFF. If the servo is ON, an alarm will occur
.
Operation procedures
1. Operate as the procedures in section 4.9 Auxiliary function and display the
2.Press the SET
button and show the
3. Long-press the LEFT
button, then display the
and flicker, then change to
4. Restart the power supply and the parameter clearing is done.