153
Figure 8.9.28 Overview diagram with horizontal axis(home position return with Home position DOG front end and phase Z)
Note) ) I/O state: “C” indicates the closed-circuit for internal output circuit contact or external contact.
“O” indicates open-circuit.
Figure 8.9.29 Timing chart ((home position return with Home position DOG front end and phase Z)
・
When set the Action at home position return completion(No. 647. 1) to “No move”, it will not shift to the home position and
end the action.
・
When set Home position Base signal 1 redetection (No. 645. 3) to “Disable”, no backward action for detecting home position
DOG front end.
・
When start the home position return on the home position sensor, it will be back to home position DOG sensor front end and
have the home position DOG front end detection with home position return creep speed.
3) About the exit of home position DOG sensor
Set the
「
Base signal 1 selection for Home position( No. 645. 0)
」
to “2 = Home position DOG front end”.
When the start point of home position return is on the home position DOG sensor, back to the position where the home
position return can proceed to start the home position return. Take it as the example with “set
「
Base signal 2 selection for
Home position(No. 645. 1
)」
to “1 = Encoder Phase Z”.