177
7. About alarms
The alarms in absolute system are shown below.
Relative to the incremental system alarm items, the absolute system adds the items of encoder error(( Err. 18)), multi-rotation
data error ((Er r. 2 0) and encoder low-voltage error(Err. 21). These alarms cannot be cleared by alarm resetting or restarting
the 24VDC control power. Restart the control power supply after encoder clearing.
Check the alarms on the [State display] screen
Table 9 Check the alarms on the [State display] screen
No.
Alarm items
Description
・
handling ways
18
Encoder error
The encoder itself error occurs.
20
Multi-rotation data error
☆
The multi-rotation data changes sharply.
☆
Check the encoder cable wiring and PIN contact
☆
Perform FG grounding and countermeasures such as separation of power
cable and encoder cable.
21
Encoder low-voltage error
☆
The multi-rotation data changes sharply.
☆
Check if the battery voltage is too low for the absolute or battery cable loosen
For alarm details of the encoder, refer to the [Encoder] on the [Auxiliary function] screen.
Table 10 Alarm details for the encoder
No.
Alarm items
Description
・
handling ways
0
Speed error
The multi-rotation ABS sensor conversion error occurs at backup or speed error
occurs at power ON
1
MR
Low battery voltage warning
2
Multi-rotation ABS
Sensor communication error, cannot get the multi-rotation data at power ON.
3
Position error
The sensor error results in the different value between the 1-rotation ABS sensor
and multi-rotation ABS sensor, which unable to confirm the encoder position.
4
Low –voltage error
Only for multi-rotation ABS encoder
The supply voltage is under the voltage specification described in the manual at
power OFF.
Summary of Contents for SV-E3 Series
Page 21: ...21 ...
Page 25: ...25 ...
Page 27: ...27 ...
Page 28: ...28 ...
Page 29: ...29 ...
Page 30: ...30 3 5 Dimensions of servo drive Same dimensions for SV E3 ...
Page 41: ...41 Figure 5 3 1 ...