Note 1) About I/O status, “C” indicates the internal output circuit contact and external contact is close, while “O” means open.
Note 2) At servo OFF, via type selection, the deceleration stop (parameter No.224.0) will be:.
a) Prompt stop or short brake via short brake deceleration stop
b) Free run, free run stop
Note 3) Deceleration stop will finish when it meets the conditions of deceleration stop at servo OFF (parameter No.224.1,
226.0, 227.0) .
Note 4) MBRK will be OFF when the deceleration stop has completed or the motor speed is below the setting value specified
in parameter No.227.0. (excluding the occurrence of the alarm in Note 6)
Note 5) The MBRK will be OFF when motor excitation is OFF, when the free run is selected in No.224.0.
Note 6) When the following alarms occur, MBRK will be OFF right after internal alarm state is ERROR ..
a) Encoder error
b) Undervoltage of control power supply
c) Inverter output error
Note 7) When the following alarms occur, the deceleration stop will be in the following ways.
a) If motor speed cannot be detected due to encoder error. It will be OFF at the operation time in No.226.0.
b) Selection of deceleration stop at the power supply voltage(No.224.2) drops. When selecting 0(=Disable), free-run
stops. When selecting 1(=Enable), it will be OFF after the operation time (No.228.0) of power supply drop deceleration stop.
As the CPU will stop immediately, the actual operation time will be shortened.
c) Free-run stops as the inverter output error( inverter error 1, overvoltage error, overcurrent error, base circuit break)..
Note 8) When the following alarms occur, SERVO signal can be delayed to deceleration stop OFF.
a) Encoder error
b) Undervoltage of control power supply