92
Return to the display to change the parameter No.
(Display parameter 2.0)
Press
button
Press UP button to change the parameter No.
Display parameter 3.0.
Press
button once
Display the setting value of parameter 3.0.
Press
button to set the related parameters. We can go to the next step after all the parameters are set.
Press
three times
Switch to the mode of setting panel.
Switch to parameter saving mode.
Press
button once
Save the parameter to the EEPROM in drive.
(When saving,
『
P
』
in
『
SAVE_P
』
will flicker.)
To the end.
-
Please cut off the power supply to the drive and restart. After restart the power, the setting
will be effective.
Note 1: The control power for models of 750W or less is supplied from external 24VDC.For 1kW or more, is supplied from
internal. Therefore, the control power for models of 1kW or more can be ON/OFF by switching on/off the AC power supply of
main circuit.
8.2 Position control mode (Pulse position command input)
8.2.1 Wiring for user I/O connector (CN1) (Differential input)
Name
Symbol
Terminal
No.
Signal name
Contents
User I/O
●24V power
supply input
●Parallel I/O
●Pulse command
input
●ABZ output
CN1
1
24V
Drive control power supply 24V input
2
G24V
Drive control power supply GND
3
COM+/-
I/O power supply 24V input
4
SVON
Servo ON input
5
RESET
Alarm reset input
6
HOLD
Command input restriction
7
PCLR
Deviation counter clear input
8
-
Reserved
9
CCWL
CCW drive input restriction
10
CWL
CW drive input restriction
11
TLSEL1
Torque limit input
12
COM-
I/O power supply GND
13
MBRK
Brake release output
14
SERVO
Servo status output
15
POSIN
Position completion output