39
[Setting method by set panel]
①
Press the MODE button three times from the initial display status. The leftmost display on the LCD (6 digits) is [P] to come to
the parameter setting mode. There is 3 digits, the point(.) and 1 digit on the right side of [P]. And the rightmost display is blank
or [r]. The parameter number is represented by 3 digits, the point(.) and 1 digit.
②
Press the UP/DOWN and SHIFT button, when [P004.0r] shows, press SET button to display the current setting value. The
initial value is [1].
③
Press the UP/DOWN and SHIFT button and input the expected communication address. Setting range is from 1 to 32.
④
Press the SET button to RAM, the indicator changes from flicker to lit.
⑤
Press the MODE button three times to display [SAVE_P].
⑥
Press the SET button, the [P] in [SAVE_P] flicker. When the parameter is stored in the EEPROM normally, [nr_End]
displays.
⑦
Notes: Cut off the power supply to the servo drive(Note1). Before restart the power supply, the servo drive operates as the
former communication address.
⑧
Set the communication address to the other drive as the same way described from
①
to
⑦
. When the single-axis drive are
used in parallel, please set the communication address by the set panel of the servo drive.
5. Panel display and operation
5.1 Overview
The functions of operation panel are as follows:
a) Status display (Status display mode)
b) Alarm display (Alarm display mode)
c) Parameter setting (Parameter setting mode)
d) Auto tuning (Auto tuning mode)
e) Parameter saving (parameter saving mode)
f) Auxiliary functions (JOG function mode, parameter clearing mode, encoder clearing mode)
5.2 Part names
Table 5.2.1 Set panel for drive
Items
Description
MODE
Change operation mode and parameters.