76
at Servo off:
cancelation
reasons
1 = Rotations of cancelation or operating time
[Initial value] 1 (Rotations of cancelation or operating time)
[Setting range] 0 or 1
224.2
[Basic setting]
Use of a
deceleration stop
in case of control
power supply
voltage drop
Enable/Disable Deceleration Stop when the voltage from a control power supply drops
by No. 228.0.
0 = Disable
1 = Enable
[Initial value] 1 (Enable)
[Setting range] 0 or 1
No
226.0
[Basic setting]
Deceleration stop :
operating time at
servo off
Set the operating time for deceleration stop at servo OFF.
(If “0(No brake)” is set to No.224, this parameter is invalid.)
[Initial value] 200W
~
750W: 313 [160
μ
s]
・・・
50ms,
1
kW
~
2kW: 250 [200
μ
s]
・・・
50ms
[Setting range] 0 to 16383
No
227.0
[Basic setting]
Cancellation
speed of
deceleration stop
and brake
cancellation OFF
at servo OFF.
Set the cancellation speed of deceleration stop at servo OFF. It sets the speed of
brake OFF cancellation.
(If “0(No brake)” is set to No.224.0 and “0(Operation time)” set to No.224.1, this
parameter is invalid.)
[Initial value] 200W
~
750W: 17[pulse/160
μ
s]
・・・
50r/min,
1
kW
~
2kW: 22[pulse/200
μ
s]
・・・
50r/min
[Setting range] 0 to 32767
No
228.0
[Basic setting]
Operating time of
deceleration stop
at control power
supply voltage
drop
Set the operating time of deceleration stop at control power supply voltage drop in
motor rotation.
[Initial value] 62 [160μs]
・・・
10ms
[Setting range] 0 to 16383 [ms]
No
237.0
[Basic setting]
Delay
time
at
servo OFF
Set the delay time between getting the input signal of Servo OFF and motor excitation
OFF.
(The disconnection of COM2 and SVON terminal indicates the servo ON input signal
is OFF.)
[Initial value] 200W
~
750W: 0[160
μ
s]
・・・
0ms,
1
kW
~
2kW: 0[200
μ
s]
・・・
0ms
[Setting range] 0 to 3125
No
238.0
[Basic setting]
Delay
time
of
brake release
Set the delay time from motor excitation start to brake release output signal (MBRK
)
ON. (The connection of COM2 and SVON terminal indicates the brake release output
signal is ON.)
[Initial value] 200W
~
750W: 25[pulse/160
μ
s],
1
kW
~
2kW: 20[pulse/200
μ
s]
[Setting range] 0 to 3125
No
257.0
[Basic setting]
Selection of an
encoder system
Select an option for Absolute system or Incremental system.
0 = Incremental system
1 = Absolute system (multi-rotation counter overflow detection disabled)
2 = Absolute system (multi-rotation counter overflow detection enabled)