General Operation
Chapter 1: Introduction
Page 1 - 28
Advanta™ Bed Service Manual (man168ra)
Standard Controls
Siderail Back Lighting
The siderails have back lights to illuminate the patient bed position controls
and make the switches more visible in dim light. The back light can be turned
on or off at the footboard control panel.
The back light on the nurse call switches cannot be turned off.
To activate: Press and release the back light switch on the footboard control
panel to turn on or off the siderail back lighting. When the green indicator light
on the back light switch is on, the function is on.
Night Light
The night light is located on the bottom center of the bed frame and can be
turned on or off as desired. An adjustable light sensor can be set to turn the
night light on when light in the room reaches a predetermined level of dimness.
Control location: Footboard control panel
To activate: Press and release the night light switch to turn on or off the night
light. When the green indicator light on the night light switch is on, the
function is on.
Night Light Sensor Control
The night light sensor control is located at the foot end of the bed frame, on the
right-hand side. It has an adjustable knob to allow you to set the level of light at
which the night light comes on.
To increase the sensitivity of the night light sensor so that the night light comes
on when the room gets somewhat dark, turn the knob clockwise.
To decrease the sensitivity of the night light sensor so that the night light
comes on when the room gets very dark, turn the knob counterclockwise.
To activate: Using a small screwdriver, insert the blade into the hole in the
center of the sensor control, and engage the slot in the night light sensor control
adjustment knob. Turn clockwise or counterclockwise, as desired.
Summary of Contents for Advanta P1600
Page 2: ......
Page 6: ...Revisions Page iv Advanta Bed Service Manual man168ra NOTES...
Page 22: ...Chapter 1 Introduction Page 1 4 Advanta Bed Service Manual man168ra NOTES...
Page 142: ...Chapter 3 Theory of Operation Page 3 4 Advanta Bed Service Manual man168ra NOTES...
Page 310: ...Warranty Chapter 5 Parts List Page 5 4 Advanta Bed Service Manual man168ra NOTES...
Page 353: ...Footboard P1606 Chapter 5 Parts List Advanta Bed Service Manual man168ra Page 5 47 5 NOTES...
Page 371: ...Power Module Chapter 5 Parts List Advanta Bed Service Manual man168ra Page 5 65 5 NOTES...
Page 386: ...Chapter 6 General Procedures Page 6 2 Advanta Bed Service Manual man168ra NOTES...
Page 404: ...Chapter 7 Accessories Page 7 2 Advanta Bed Service Manual man168ra NOTES...
Page 412: ...Schematic Wiring Diagram Patient Switch Board P N 67208 FO 3 2 m168a103 Back to Chapter 3...
Page 413: ...Schematic Wiring Diagram J Box UTV Board P N 64935 FO 3 3 m168_107 Back to Chapter 3...
Page 417: ...Schematic Wiring Diagram Logic Board PN 63285 FO 3 7 m168_115 Back to Chapter 3...
Page 418: ...Schematic Wiring Diagram Power Board PN 63349 FO 3 8 m168_118 Back to Chapter 3...
Page 419: ...Schematic Wiring Diagram Frame Interface Board PN 63352 FO 3 9 m168_120 Back to Chapter 3...
Page 422: ...Schematic Wiring Diagram Sensor Board PN 4474001 FO 3 12 m168_128 Back to Chapter 3...
Page 425: ...Schematic Wiring Diagram Head Sensor Assembly P N 63888 FO 3 14 m168a186 Back to Chapter 3...
Page 427: ...Schematic Wiring Diagram HIlow Knee Sensor PN 63885 FO 3 16 m168_178 Back to Chapter 3...