Online Operation
5-39
•
01
- indicates the DS1a DS0 channel number is connected to DS1b DS0
channel number 1. Possible displays are
01
through
24
.
Press the
Escape
button to return to the DS1a Diagnostic Status submenu.
10. Press the button beneath
Bndle
. The ISX 5312/5314 performs bidirectional
bundle loops. This means that all the DS0s assigned to both lines in a
connection are looped. The screen displays whether DS1a has a bundle loop in
progress with DS1b.
Off
indicates the loop is inactive.
On
indicates it is active.
1
2
3
4
E scape
Top
L
D S U D S 1 a D i a g S t a t u s
L i n e C h a n B n d l e T s t P a t
L
D S 1 b B u n d l e L o o p : O f f
<
>
Press the
Escape
button to return to the DS1a Diagnostic Status submenu.
11. Press the button beneath
TstPat
. The screen displays whether a Pattern Test is in
progress on the DS1a line.
Off
indicates the test is inactive.
On
indicates it is
active.
1
2
3
4
E sca pe
T o p
L
D S U D S 1 a D i a g S t a t u s
L i n e C h a n B n d l e T s t P a t
L
D S U D S 1 a D i a g S t a t u s
D S 1 a T e s t P a t t : O f f
<
>
Follow steps 12 and 13 if you want to check the status of the alarm relay contacts on a
central site model ISX 5314.