11-5
Seiko Epson Corporation
S1C31D50 TECHNICAL MANUAL
(Rev. 1.00)
Intermittent operation mode
SVD3 operates in intermittent operation mode when the SVD3CTL.SVDMD[1:0] bits are set to 0x1 to
0x3. In this mode, SVD3 turns on at an interval set using the SVD3CTL.SVDMD[1:0] bits to perform
detection operation and then it turns off while the SVD3CTL.MODEN bit is set to 1. During this
period, the latest detection results can be obtained by reading the SVD3INTF.SVDDT bit as necessary.
Furthermore, an interrupt or a reset can be generated when SVD3 has successively detected low
power supply voltage the number of times specified by the SVD3CTL.SVDSC[1:0] bits.
(1)
When the SVD3CTL.SVDMD[1:0] bits = 0x0 (continuous operation mode)
(2)
When the SVD3CTL.SVDMD[1:0] bits
≠
0x0 (intermittent operation mode)
Figure 11.4.2.1 SVD3 Operations
V
DD
SVD3CTL.MODEN
SVD3 operating status
V
SVD
V
SVD
DET
SVD3INTF.SVDDT
Low power supply voltage
detection interrupt
DET
DET
V
DD
SVD3CTL.MODEN
SVD3 operating status
SVD3INTF.SVDDT
Low power supply voltage
detection interrupt
V
SVD
V
SVD
VSVD : Level set using the SVD3CTL.SVDC[4:0] bits
: Voltage detection masking time
: Voltage detection operation
DET
Summary of Contents for S1C31D50
Page 461: ...25 1 Seiko Epson Corporation S1C31D50 TECHNICAL MANUAL Rev 1 00 25 Package TQFP12 48PIN ...
Page 462: ...25 2 Seiko Epson Corporation S1C31D50 TECHNICAL MANUAL Rev 1 00 QFP13 64PIN ...
Page 463: ...25 3 Seiko Epson Corporation S1C31D50 TECHNICAL MANUAL Rev 1 00 TQFP14 80PIN ...
Page 464: ...25 4 Seiko Epson Corporation S1C31D50 TECHNICAL MANUAL Rev 1 00 QFP15 100PIN ...