B-2
Seiko Epson Corporation
S1C31D50 TECHNICAL MANUAL
(Rev. 1.00)
0x0020 0000 System Register (SYS)
Address
Register name
Bit
Bit name
Initial
Reset
R/W
Remarks
0x0020
0000
SYSPROT
(System Protect
Register)
15
–
0
PROT[15:0]
0x0000
H0
R/W
–
0x0020 0020 Power Generator (PWGA)
Address
Register name
Bit
Bit name
Initial
Reset
R/W
Remarks
0x0020
0020
PWGACTL
(PWGA Control
Register)
15
–
8
–
0x00
–
R
–
7
–
6
–
0x0
–
R
5
REGDIS
0
H0
R/WP
4
REGSEL
1
H0
R/WP
3
–
2
–
0x0
–
R
1
–
0
REGMODE[1:0]
0x0
H0
R/WP
0x0020 0040
–
0x0020 0054 Clock Generator (CLG)
Address
Register name
Bit
Bit name
Initial
Reset
R/W
Remarks
0x0020
0040
CLGSCLK
(CLG System
Clock Control
Register)
15
WUPMD
0
H0
R/WP
–
14
–
0
–
R
13
–
12 WUPDIV[1:0]
0x0
H0
R/WP
11
–
10
–
0x0
–
R
9
–
8
WUPSRC[1:0]
0x0
H0
R/WP
7
–
6
–
0x0
–
R
5
–
4
CLKDIV[1:0]
0x2
H0
R/WP
3
–
2
–
0x0
–
R
1
–
0
CLKSRC[1:0]
0x0
H0
R/WP
0x0020
0042
CLGOSC
(CLG Oscillation
Control Register)
15
–
12
–
0x0
–
R
–
11
EXOSCSLPC
1
H0
R/W
10
OSC3SLPC
1
H0
R/W
9
OSC1SLPC
1
H0
R/W
8
IOSCSLPC
1
H0
R/W
7
–
4
–
0x0
–
R
3
EXOSCEN
0
H0
R/W
2
OSC3EN
0
H0
R/W
1
OSC1EN
0
H0
R/W
0
IOSCEN
1
H0
R/W
0x0020
0044
CLGIOSC
(CLG IOSC
Control Register)
15
–
8
–
0x00
–
R
–
7
–
2
–
0x00
–
R
1
–
0
IOSCFQ[1:0]
0x2
H0
R/WP
0x0020
0046
CLGOSC1
(CLG OSC1
Control Register)
15
–
0
–
R
–
14
OSDRB
1
H0
R/WP
13
OSDEN
0
H0
R/WP
12
OSC1BUP
1
H0
R/WP
11
OSC1SELCR
0
H0
R/WP
10
–
8
CGI1[2:0]
0x0
H0
R/WP
7
–
6
INV1B[1:0]
0x2
H0
R/WP
5
–
4
INV1N[1:0]
0x1
H0
R/WP
3
–
2
–
0x0
–
R
1
–
0
OSC1WT[1:0]
0x2
H0
R/WP
Summary of Contents for S1C31D50
Page 461: ...25 1 Seiko Epson Corporation S1C31D50 TECHNICAL MANUAL Rev 1 00 25 Package TQFP12 48PIN ...
Page 462: ...25 2 Seiko Epson Corporation S1C31D50 TECHNICAL MANUAL Rev 1 00 QFP13 64PIN ...
Page 463: ...25 3 Seiko Epson Corporation S1C31D50 TECHNICAL MANUAL Rev 1 00 TQFP14 80PIN ...
Page 464: ...25 4 Seiko Epson Corporation S1C31D50 TECHNICAL MANUAL Rev 1 00 QFP15 100PIN ...