7-13
Seiko Epson Corporation
S1C31D50 TECHNICAL MANUAL
(Rev. 1.00)
P Port Interrupt Flag Group Register
Register name
Bit
Bit name
Initial
Reset
R/W
Remarks
PPORTINTFGRP
15
–
13
–
0x0
–
R
–
12
PCINT
0
H0
R
11
PBINT
0
H0
R
10
PAINT
0
H0
R
9
P9INT
0
H0
R
8
P8INT
0
H0
R
7
P7INT
0
H0
R
6
P6INT
0
H0
R
5
P5INT
0
H0
R
4
P4INT
0
H0
R
3
P3INT
0
H0
R
2
P2INT
0
H0
R
1
P1INT
0
H0
R
0
P0INT
0
H0
R
*1: Only the bits corresponding to the port groups that support interrupts are provided.
Bits 15
–
11 Reserved
Bits 10
–
0
P
x
INT
These bits indicate that P
x
port group includes a port that has generated an interrupt.
1 (R): A port generated an interrupt
0 (R): No port generated an interrupt
The PPORTINTFGRP.P
x
INT bit is cleared when the interrupt flag for the port that has
generated an interrupt is cleared.