91
Eaton RF-System
© 2015 Eaton Electrical Group
actuator
Multi-Heating actuator as Heating-/Cooling-request:
In this configuration the connected channel of the Multi-Heating actuator is allowed to work in both
operation types. Only one operation type must be active at a time (Only Heating or Only Cooling).
Further possible request connections for Room: other channels of Multi-Heating actuator
Outputs and the Room Manager
In the Room Manager you can define up to 10 different outputs (independent if single or
multiswitching of actuators).
By using the sensor wheel you can operate the outputs (On, Off, Dim,..).
Devices that can be assigned to a output are switching actuator, dimming actuator, analogue
actuator, shutter actuator, Comm.-interface and Home Manager.
Shutter actuators can only be used with shading and not with normal outputs.
Devices that have a direct RF-connection to the Room Manager are sending its state to the Room
Manager whenever it changes. The actual state is also displayed in the output page of the Room
Manager.
The name of the output can be changed in the Room Manager directly or in the MRF programme.
Additional the basic state after a reset of the Room Manager can be set for every output in the
MRF software.
Summary of Contents for RF System 2.42
Page 1: ...Eaton RF System 2 42 Manual...
Page 123: ...123 Eaton RF System 2015 Eaton Electrical Group State Syntax of RM to user...
Page 193: ...193 Eaton RF System 2015 Eaton Electrical Group...
Page 200: ...200 Eaton RF System Help 2015 Eaton Electrical Group 7 And assign the function Blinking to it...
Page 223: ...223 Eaton RF System 2015 Eaton Electrical Group Group settings analogue actuator...
Page 224: ...224 Eaton RF System Help 2015 Eaton Electrical Group Group settings heating actuator...
Page 225: ...225 Eaton RF System 2015 Eaton Electrical Group Group settings binary input battery supplied...
Page 227: ...227 Eaton RF System 2015 Eaton Electrical Group Group settings Temperature input...