For a battery-supplied binary input you can also select how it should behave when the switching
contact opens.
Note: A fast reaction impacts the battery life negatively.
Room Controller
The room controller serves as a sensor and can control all xComfort actuators (switching actuator,
dimming actuator, shutter actuator, etc.); it can also send information (temperature) to the Home
Manager, Room Manager, etc.
In order to scan the room controller, turn the adjustment wheel to the upper/lower stop or actuate
the activating keys (types CRCA-00/02 and CRCA-00/03 only)
It has an internal temperature sensor (0 to max. 40°C) and a transmitter for the desired
temperature, which allows to change the desired temperature by ±3°C with an adjustment wheel.
You can choose between the two modes (Send switching commands, Send measured value) via
the settings window.
Sending a switching command: