In this case the direct measured value (0-100%) is sent to a dimming actuator or analog actuator.
An upper and lower limit can be set (if the measured value falls outside these limits, the limit value
is the maximum value sent) and the value can be inverted.
This setting can be used to control the brightness in a room as a function of external brightness,
for example….
2-fold remote control:
This device is a battery-powered sensor which can control all xComfort actuators (switching
actuator, dimming actuator, shutter actuator, etc.), but it can also send commands to the Home
Manager, Room Manager, etc. (e.g. to start complex processes).
The functions of this remote control are almost identical to a 2x button.
In the case of commands from the 2x remote control, we have to distinguish between the right and
left switch rocker.
The LED on the top left side shows when a command is sent (flashes briefly once) and when the
command has been acknowledged by the destination device (or the next device in the event of
routing) (flashes briefly twice). When the command has been successfully sent and acknowledged,
the LED then flashes three times.
Each rocker sends the following commands:
: short press on the button, top
Summary of Contents for RF System 2.42
Page 1: ...Eaton RF System 2 42 Manual...
Page 123: ...123 Eaton RF System 2015 Eaton Electrical Group State Syntax of RM to user...
Page 193: ...193 Eaton RF System 2015 Eaton Electrical Group...
Page 200: ...200 Eaton RF System Help 2015 Eaton Electrical Group 7 And assign the function Blinking to it...
Page 223: ...223 Eaton RF System 2015 Eaton Electrical Group Group settings analogue actuator...
Page 224: ...224 Eaton RF System Help 2015 Eaton Electrical Group Group settings heating actuator...
Page 225: ...225 Eaton RF System 2015 Eaton Electrical Group Group settings binary input battery supplied...
Page 227: ...227 Eaton RF System 2015 Eaton Electrical Group Group settings Temperature input...