188
Eaton RF-System - Help
© 2015 Eaton Electrical Group
output action for Release Lock can be defined (ON, OFF, old value)
No Function, occupies 1 command button
Has no Function, However the actuator will send a Resend of the RF-command if in a
group
Output-States of the Switching actuator:
A change between the different Switching-States of the Switching actuator will trigger a Status
Message to connected devices. Depending on the type of the intelligent device (old or new) the
Status message will be sent in the old format or in the new extended format (see extended status
message).
The following states are possible:
ON – the output is ON
OFF – the output is OFF
Blinking – the actuator is just executing a blink function, the output state cannot be definitely ON or
OFF as it changes over time
ON locked – The output is ON and any further operation by a normal switch function is not
possible at the moment (exception ‚Release Lock‘)
OFF locked – The output is OFF and any further operation by a normal switch function is not
possible at the moment (exception ‚Release Lock‘)
OFF over temperature – The output is OFF because the maximum internal temperature has been
exceeded. An operation that switches the output ON again is only possible if the internal
temperature falls below 15°C of the maximum value.
Functions for Pushbuttons, Remote control, intelligent devices and Binary inputs Mode 4:
On / Off (Standard)
ON /
OFF,
and
free, only for
selectable
On / Switch-on Delay free selectable for
,
,
and
Off / On with Switch-Off delay free selectable for
,
,
and
Off / Switch-off Delay free selectable for
,
,
and
Off with Advance Warning free selectable for
,
,
and
Push-button/Key Mode for
,
or
,
; only for
oder
selectable
Surge only for
and
selectable
Blinking free selectable for
,
,
and
Activate Lock free selectable for
,
,
and
Release Lock free selectable for
,
,
and
Functions for Binary inputs Mode 1, Binary inputs Mode 3 (Pushbutton) and local inputs Mode 1:
Surge (Standard) only for
selectable
On / Switch-on Delay free selectable for
and
Off / On with Switch-Off delay free selectable for
and
Off / Switch-off Delay free selectable for
and
Off with Advance Warning free selectable for
and
Push-button/Key Mode for
and
, only for
selectable
Blinking free selectable for
and
Activate Lock free selectable for
and
Release Lock free selectable for
and
Functions for Binary input Mode 2 and 3 (Switch), Motion detector and local input Mode 2:
On / Off (Standard)
ON /
OFF, only for
selectable
On / Switch-on Delay free selectable for
and
Off / On with Switch-Off delay free selectable for
and
Off / Switch-off Delay free selectable for
and
Summary of Contents for RF System 2.42
Page 1: ...Eaton RF System 2 42 Manual...
Page 123: ...123 Eaton RF System 2015 Eaton Electrical Group State Syntax of RM to user...
Page 193: ...193 Eaton RF System 2015 Eaton Electrical Group...
Page 200: ...200 Eaton RF System Help 2015 Eaton Electrical Group 7 And assign the function Blinking to it...
Page 223: ...223 Eaton RF System 2015 Eaton Electrical Group Group settings analogue actuator...
Page 224: ...224 Eaton RF System Help 2015 Eaton Electrical Group Group settings heating actuator...
Page 225: ...225 Eaton RF System 2015 Eaton Electrical Group Group settings binary input battery supplied...
Page 227: ...227 Eaton RF System 2015 Eaton Electrical Group Group settings Temperature input...