115
Eaton RF-System
© 2015 Eaton Electrical Group
Tariff per measuring unit: Enter the tariff per measuring unit here
CO2 per kWh: Here you can enter the CO2 coefficient per kWh
Surveillance of threshold values:
Threshold value: Enter the threshold value here
kWh /: Here you can select the time period to be kept under surveillance or select the active
power directly
In case of exceeding the value: Here you can set the action to be taken in case the threshold value
is exceeded
Display alarm: If this option has been activated and if the threshold value is exceeded, a short info
page will appear at the Room Manager Display. This info page needs to be acknowledged.
Display on the Room Manager:
In 3 double-lines you can have the different consumption values displayed. The settings made
here will be visualized at the display of the Room Manager, but they can be changed at any time
again via the Settings menu in the Room Manager.
Settings possible for the display (dependend on if consumer of generator is selected):
Values for xC MEP device total energy channel: total active power consumption, total power
production, total energy consumption, total energy production, present tariff
Values for xC MEP device rate enegy channel: Energy consumption, Energy production, costs,
CO2 consumption, consumption forecast, production forecast, cost forecast, gain forecast, CO2
forecast,
Time periods: Last hour, 24 hours, since mid-night, 7 days, since the beginning of the week, 30
days, since the beginning of the month, since the beginning of the year, total value, Alltime
Not every period of time can be selected for every value though.
Also refer to chapter
General Information on the Room Manager with Energy Function
Room-Manager with Energy Function - Energy General page:
The page is used as additional display to get a quick overview of the present consumption or
production. Further it is possible to define actions for defined consumption or production areas.
Summary of Contents for RF System 2.42
Page 1: ...Eaton RF System 2 42 Manual...
Page 123: ...123 Eaton RF System 2015 Eaton Electrical Group State Syntax of RM to user...
Page 193: ...193 Eaton RF System 2015 Eaton Electrical Group...
Page 200: ...200 Eaton RF System Help 2015 Eaton Electrical Group 7 And assign the function Blinking to it...
Page 223: ...223 Eaton RF System 2015 Eaton Electrical Group Group settings analogue actuator...
Page 224: ...224 Eaton RF System Help 2015 Eaton Electrical Group Group settings heating actuator...
Page 225: ...225 Eaton RF System 2015 Eaton Electrical Group Group settings binary input battery supplied...
Page 227: ...227 Eaton RF System 2015 Eaton Electrical Group Group settings Temperature input...