Ending the milling operation
Stop the machine and raise at the end of the milling lane:
- The drive lever (70) is located in centre position.
- If the automatic levelling device is used for milling, first shut down the levelling unit
using switches (37) and (38).
- Change over selector switch for front scraper (35)(
&
) and moldboard (34) to „0“.
- Raise machine uniformly by pressing both switches (73) + (74) together until the
desired ground clearance has been reached. Where applicable, press the switch
for raising and lowering speed (36) to rapid adjustment beforehand.
- Allow milling drum transmission (31), water pump (33) and upper conveyor (24) to
run on briefly, then switch to „0“.
- Move switch (28) to transportation speed (hare).
- Set preselector controller for driving speed (27) to around 50%.
- Start to move the machine by deflecting the drive lever out of its centre position and
move out of the construction site area. If necessary, use the preselector controller
(27) to slowly increase the driving speed.
- Where necessary, guide the upper conveyor using the control lever (71).
$
Comply with safety regulations when moving the machine outside the construction
site!
71
70
73
74
28
27
36
32
35
31
34
33
Panel2_500_1000.wmf/Panel4_V2.bmp
38
37
Summary of Contents for PL 500/20 S
Page 2: ...VALUE QUALITY THE ORIGINAL Your authorised Dynapac dealer SPARE PARTS...
Page 10: ......
Page 21: ...B 9 B PL500 20S GB 9 20 04 07 PL500_measure_side_short wmf PL500_measure_top_short wmf...
Page 27: ...B 15 B PL500 20S GB 15 20 04 07 5 2 Identification points 8 10 2 2 9 3 7 6 4 2 12 1 2 5 25 11...
Page 28: ...B 16 B PL500 20S GB 16 20 04 07 14 13 16 16 3 17 20 19 2 2 18 13 21 22 23 24 14...
Page 32: ......
Page 40: ......
Page 44: ...D 4 D PL500 20S GB 4 116 04 07 Panel3_V2 bmp A 4 7 6 9 10 8 5...
Page 66: ...D 26 D PL500 20S GB 26 116 04 07 Panel4_1000 cdr D 73 74 70 75 77 78 76 71 72...
Page 68: ...D 28 D PL500 20S GB 28 116 04 07 Panel4_1000 cdr D 73 74 70 75 77 78 76 71 72...
Page 70: ...D 30 D PL500 20S GB 30 116 04 07 Panel4_1000 cdr D 73 74 70 75 77 78 76 71 72...
Page 92: ...D 52 D PL500 20S GB 52 116 04 07 5 Operating the MOBA matic Nivellcompl cdr A C B...
Page 96: ...D 56 D PL500 20S GB 56 116 04 07 Moba1can jpg M10 A C M2 M3 M6 M7 M9 M8 M4 M5 M1 M11...
Page 156: ...D 116 D PL500 20S GB 116 116 04 07 10 4 MOBA Matic error messages...
Page 183: ...F 23 F PL500 20S GB 23 74 04 07 Box1_Pl500_V2 wmf Box5_PL500 wmf 8 2 3 4 5 A B C D E 7 9 1 6...