LED Codes
If the system does not enter console mode (>>>), or if the hex
code DD is not displayed on the LEDs, then use Table 10–4 to
isolate the failed FRU. Take the following action in the order
listed.
1.
Reseat the I/O module.
2.
Reseat the modem loopback.
3.
Reseat the mouse connection.
4.
Reseat the keyboard connection.
Note
When testing a DEC 3000 Model 800S AXP system,
the console command SERVER must be set to ON (SET
SERVER ON) for this diagnostic.
This portion of the testing is not displayed on the monitor.
Table 10–4 SCC LED Error Codes
LED Codes
40
41
42
43
44
45
46
LED code 47 is for the keyboard and I/O module. LED code 48 is
for the mouse. LED codes 49 through 4E are reserved.
NI LED Codes
The following LED codes represent continued power-up testing.
If an error occurs during this testing sequence, the system
hexadecimal code plus FRU and error code information appear
on the screen.
If the system enters console mode, then run the NI diagnostics
and interpret the error information using:
•
SHOW ERROR command
•
Diagnostic information (Chapter 9)
•
Diagnostic error messages (Chapter 14)
10–7
Summary of Contents for DEC 3000 600 AXP
Page 57: ...BA47X AA Vertical Floor Stand Figure 3 8 Removing the Mounting Plate MLO 011165 4 5 3 12...
Page 60: ...System Cover Figure 3 9 Removing the System Cover MLO 008608 2 2 1 0 1 3 15...
Page 65: ...Removable Media Devices Figure 3 11 Loosening the Screws on the Bracket MLO 011167 1 3 20...
Page 81: ...I O Board Figure 3 18 Removing the I O Board 1 2 3 3 4 MLO 011172 3 36...
Page 149: ...Front View Figure 6 1 Front View Line In 1 2 3 4 5 MLO 007553 7 8 9 10 11 12 6 14 13 6 6...
Page 152: ...Rear View Figure 6 2 Rear View ISDN S3 1 3 4 5 6 8 10 11 MLO 010854 2 1 0 3 4 5 2 7 9 6 9...
Page 189: ...Power Supply Figure 8 10 Removing the Power Supply MLO 011224 3 4 2 8 20...
Page 193: ...RZxx Disk Drives Figure 8 11 Removing an RZxx Drive 1 2 4 3 MLO 011225 8 24...
Page 199: ...I O Module Figure 8 14 I O Module Cable Connections 2 1 0 MLO 011227 ISDN S3 3 4 5 1 8 30...
Page 200: ...I O Module Figure 8 15 Removing the I O Module Side View MLO 011228 2 3 4 5 6 8 31...
Page 204: ...Fans Figure 8 17 Removing a Fan 1 Front 2 3 4 MLO 011229 8 35...
Page 207: ...Memory Mother Board Figure 8 18 Removing a Memory Mother Board MLO 011230 1 2 8 38...
Page 210: ...Memory Module Figure 8 19 Removing SIMMs 1 2 MLO 011231 8 41...
Page 430: ...Setting a Unique SCSI Address the OpenVMS AXP and DEC OSF 1 AXP operating systems 16 4...
Page 461: ......