LED Codes
Table 14–1 (Cont.) Power-Up Test Serial ROM Codes
LED
Code
Test Description
Reason for Failure
F9
Memory test with non-BCACHE
bit CLEAR, Dcache OFF, and mchk
enabled.
If read as .NE. write, send error dump
to SROM port and branch to SROM
miniconsole.
F8
Memory test with non-BCACHE bit
SET, Dcache ON, and mchk enabled.
If read as .NE. write, send error dump
to SROM port and branch to SROM
miniconsole.
F7
Memory test with non-BCACHE
bit CLEAR, Dcache ON, and mchk
enabled.
If read as .NE. write, send error dump
to SROM port and branch to SROM
miniconsole.
F6
tc register test and initialization
Should never stop here. If read as .NE.
write, send error dump to SROM port.
F5
Coreio register test and initialization
Should never stop here. If read as .NE.
write, send error dump to SROM port.
F2
Look for I/O ROM manfacturing
data.
Read of I/O ROM manfacturing data
did not return data expected. Send
error dump to SROM port and branch
to SROM miniconsole.
F1
Completed load of I/O ROM into
memory.
Should never stop here.
30
SROM code execution completed
normally.
Should never stop here.
20
Machine check.
Send mchk dump to SROM port and to
SROM miniconsole.
If a failure occurs during this portion of the power-up procedure,
perform the following steps:
1.
Verify that there is a good connection between the system
module and I/O module.
2.
Verify that all memory modules are properly installed. You
may need to reseat memory modules.
14–3
Summary of Contents for DEC 3000 600 AXP
Page 57: ...BA47X AA Vertical Floor Stand Figure 3 8 Removing the Mounting Plate MLO 011165 4 5 3 12...
Page 60: ...System Cover Figure 3 9 Removing the System Cover MLO 008608 2 2 1 0 1 3 15...
Page 65: ...Removable Media Devices Figure 3 11 Loosening the Screws on the Bracket MLO 011167 1 3 20...
Page 81: ...I O Board Figure 3 18 Removing the I O Board 1 2 3 3 4 MLO 011172 3 36...
Page 149: ...Front View Figure 6 1 Front View Line In 1 2 3 4 5 MLO 007553 7 8 9 10 11 12 6 14 13 6 6...
Page 152: ...Rear View Figure 6 2 Rear View ISDN S3 1 3 4 5 6 8 10 11 MLO 010854 2 1 0 3 4 5 2 7 9 6 9...
Page 189: ...Power Supply Figure 8 10 Removing the Power Supply MLO 011224 3 4 2 8 20...
Page 193: ...RZxx Disk Drives Figure 8 11 Removing an RZxx Drive 1 2 4 3 MLO 011225 8 24...
Page 199: ...I O Module Figure 8 14 I O Module Cable Connections 2 1 0 MLO 011227 ISDN S3 3 4 5 1 8 30...
Page 200: ...I O Module Figure 8 15 Removing the I O Module Side View MLO 011228 2 3 4 5 6 8 31...
Page 204: ...Fans Figure 8 17 Removing a Fan 1 Front 2 3 4 MLO 011229 8 35...
Page 207: ...Memory Mother Board Figure 8 18 Removing a Memory Mother Board MLO 011230 1 2 8 38...
Page 210: ...Memory Module Figure 8 19 Removing SIMMs 1 2 MLO 011231 8 41...
Page 430: ...Setting a Unique SCSI Address the OpenVMS AXP and DEC OSF 1 AXP operating systems 16 4...
Page 461: ......