FRU Code Table
TURBOchannel
Options FRU
Codes
Table 4–2 shows the TURBOchannel options FRU codes and
their meaning.
Table 4–2 TURBOchannel Options FRU Codes
FRU Code
Meaning
010
Failed FRU is most likely TURBOchannel
option 0.
011
Failed FRU is most likely TURBOchannel
option 1.
012
Failed FRU is most likely TURBOchannel
option 2.
013-FF
Reserved
SCSI Device
FRU Codes
Table 4–3 shows the SCSI device FRU codes and their meaning.
Table 4–3 TURBOchannel Options FRU Codes
FRU Code
Meaning
1TL
SCSI device on bus A (internal), Target T,
Logical unit L (for example, FRU code for
DKA0 is 100)
2TL
SCSI device on bus B (external), Target T,
Logical unit L
Diagnostic Listing
Diagnostic
Listing
A diagnostic test is a composite of a string of subtests. You can
select a sub-test to be executed rather than executing the full
device test.
When a device is selected without specifying a sub-test, all
subtests are executed.
4–5
Summary of Contents for DEC 3000 600 AXP
Page 57: ...BA47X AA Vertical Floor Stand Figure 3 8 Removing the Mounting Plate MLO 011165 4 5 3 12...
Page 60: ...System Cover Figure 3 9 Removing the System Cover MLO 008608 2 2 1 0 1 3 15...
Page 65: ...Removable Media Devices Figure 3 11 Loosening the Screws on the Bracket MLO 011167 1 3 20...
Page 81: ...I O Board Figure 3 18 Removing the I O Board 1 2 3 3 4 MLO 011172 3 36...
Page 149: ...Front View Figure 6 1 Front View Line In 1 2 3 4 5 MLO 007553 7 8 9 10 11 12 6 14 13 6 6...
Page 152: ...Rear View Figure 6 2 Rear View ISDN S3 1 3 4 5 6 8 10 11 MLO 010854 2 1 0 3 4 5 2 7 9 6 9...
Page 189: ...Power Supply Figure 8 10 Removing the Power Supply MLO 011224 3 4 2 8 20...
Page 193: ...RZxx Disk Drives Figure 8 11 Removing an RZxx Drive 1 2 4 3 MLO 011225 8 24...
Page 199: ...I O Module Figure 8 14 I O Module Cable Connections 2 1 0 MLO 011227 ISDN S3 3 4 5 1 8 30...
Page 200: ...I O Module Figure 8 15 Removing the I O Module Side View MLO 011228 2 3 4 5 6 8 31...
Page 204: ...Fans Figure 8 17 Removing a Fan 1 Front 2 3 4 MLO 011229 8 35...
Page 207: ...Memory Mother Board Figure 8 18 Removing a Memory Mother Board MLO 011230 1 2 8 38...
Page 210: ...Memory Module Figure 8 19 Removing SIMMs 1 2 MLO 011231 8 41...
Page 430: ...Setting a Unique SCSI Address the OpenVMS AXP and DEC OSF 1 AXP operating systems 16 4...
Page 461: ......