NI Diagnostic Error Codes
Error Code
Description
4E
LANCE internal loopback/DMA: unknown tx or rx
error.
50
LANCE interrupts: initialization failed.
52
LANCE interrupts: TC Interrupt register bit not
set.
54
LANCE interrupts: SIR NI Interrupt register bit
not set.
56
LANCE interrupts: NI ISR not entered.
60
LANCE CRC: initialization failed.
62
LANCE CRC: transmit failed.
64
LANCE CRC: receive failed.
66
LANCE CRC: packet comparison failed.
68
LANCE CRC: LANCE generated bad CRC.
6A
LANCE CRC: LANCE rejected good CRC.
6C
LANCE CRC: LANCE accepted bad CRC.
6E
LANCE CRC: Other error.
70
LANCE rx MISS/BUFF: initialization failed.
72
LANCE rx MISS/BUFF: transmit failed.
74
LANCE rx MISS/BUFF: unknown receive error.
76
LANCE rx MISS/BUFF: MISS error not flagged.
78
LANCE rx MISS/BUFF: BUFF error not flagged.
80
LANCE collision: initialization failed.
82
LANCE collision: unknown transmit error.
84
LANCE collision: RETRY not flagged.
86
LANCE collision: transmitter disabled.
90
LANCE address filtering: initialization failed.
92
LANCE address filtering: transmit failed.
94
LANCE address filtering: receive failed.
96
LANCE address filtering: packet comparison
failed.
98
LANCE address filtering: broadcast filtering
failed.
9A
LANCE address filtering: promiscuous mode
failed.
9C
LANCE address filtering: null destination
accepted.
9E
LANCE address filtering: good logical address
rejected.
A0
LANCE external loopback: initialization failed.
A2
LANCE external loopback: transmit failed.
A4
LANCE external loopback: receive failed.
A6
LANCE external loopback: packet comparison
failed.
14–18
Summary of Contents for DEC 3000 600 AXP
Page 57: ...BA47X AA Vertical Floor Stand Figure 3 8 Removing the Mounting Plate MLO 011165 4 5 3 12...
Page 60: ...System Cover Figure 3 9 Removing the System Cover MLO 008608 2 2 1 0 1 3 15...
Page 65: ...Removable Media Devices Figure 3 11 Loosening the Screws on the Bracket MLO 011167 1 3 20...
Page 81: ...I O Board Figure 3 18 Removing the I O Board 1 2 3 3 4 MLO 011172 3 36...
Page 149: ...Front View Figure 6 1 Front View Line In 1 2 3 4 5 MLO 007553 7 8 9 10 11 12 6 14 13 6 6...
Page 152: ...Rear View Figure 6 2 Rear View ISDN S3 1 3 4 5 6 8 10 11 MLO 010854 2 1 0 3 4 5 2 7 9 6 9...
Page 189: ...Power Supply Figure 8 10 Removing the Power Supply MLO 011224 3 4 2 8 20...
Page 193: ...RZxx Disk Drives Figure 8 11 Removing an RZxx Drive 1 2 4 3 MLO 011225 8 24...
Page 199: ...I O Module Figure 8 14 I O Module Cable Connections 2 1 0 MLO 011227 ISDN S3 3 4 5 1 8 30...
Page 200: ...I O Module Figure 8 15 Removing the I O Module Side View MLO 011228 2 3 4 5 6 8 31...
Page 204: ...Fans Figure 8 17 Removing a Fan 1 Front 2 3 4 MLO 011229 8 35...
Page 207: ...Memory Mother Board Figure 8 18 Removing a Memory Mother Board MLO 011230 1 2 8 38...
Page 210: ...Memory Module Figure 8 19 Removing SIMMs 1 2 MLO 011231 8 41...
Page 430: ...Setting a Unique SCSI Address the OpenVMS AXP and DEC OSF 1 AXP operating systems 16 4...
Page 461: ......