Entering/Exiting Console and Service Mode
Exiting Console
Mode
Issue one of the following console commands at the console
prompt to exit console mode and enter program mode.
Note
If memory tests are run and the contents of memory
are changed, then the CONTINUE command causes a
system failure. This is normal operation since you have
overwritten the program information.
•
BOOT
Issuing the BOOT command initiates a system bootstrap
operation. See Chapter 13.
•
CONTINUE
Issuing the CONTINUE command clears the RC State Flag
bit and resumes processor execution. See Chapter 13.
Note
If memory tests are run and the contents of memory
is changed, then the CONTINUE command causes a
system failure. This is a normal operation since you have
overwritten the program information.
•
SET DIAG_SECTION 2
Console mode can be exited and service mode entered by
using the SET DIAG_SECTION 2 command. Setting the
diagnostic environment to service mode allows for extended
testing of certain diagnostics. To enter service mode, enter:
>>> SET DIAG_SECTION 2
Return
Entering
Service Mode
Some diagnostics require that service mode be used when
testing. To enter service mode, you must first enter console
mode. At the console prompt, enter:
>>> SET DIAG_SECTION 2
Return
4–11
Summary of Contents for DEC 3000 600 AXP
Page 57: ...BA47X AA Vertical Floor Stand Figure 3 8 Removing the Mounting Plate MLO 011165 4 5 3 12...
Page 60: ...System Cover Figure 3 9 Removing the System Cover MLO 008608 2 2 1 0 1 3 15...
Page 65: ...Removable Media Devices Figure 3 11 Loosening the Screws on the Bracket MLO 011167 1 3 20...
Page 81: ...I O Board Figure 3 18 Removing the I O Board 1 2 3 3 4 MLO 011172 3 36...
Page 149: ...Front View Figure 6 1 Front View Line In 1 2 3 4 5 MLO 007553 7 8 9 10 11 12 6 14 13 6 6...
Page 152: ...Rear View Figure 6 2 Rear View ISDN S3 1 3 4 5 6 8 10 11 MLO 010854 2 1 0 3 4 5 2 7 9 6 9...
Page 189: ...Power Supply Figure 8 10 Removing the Power Supply MLO 011224 3 4 2 8 20...
Page 193: ...RZxx Disk Drives Figure 8 11 Removing an RZxx Drive 1 2 4 3 MLO 011225 8 24...
Page 199: ...I O Module Figure 8 14 I O Module Cable Connections 2 1 0 MLO 011227 ISDN S3 3 4 5 1 8 30...
Page 200: ...I O Module Figure 8 15 Removing the I O Module Side View MLO 011228 2 3 4 5 6 8 31...
Page 204: ...Fans Figure 8 17 Removing a Fan 1 Front 2 3 4 MLO 011229 8 35...
Page 207: ...Memory Mother Board Figure 8 18 Removing a Memory Mother Board MLO 011230 1 2 8 38...
Page 210: ...Memory Module Figure 8 19 Removing SIMMs 1 2 MLO 011231 8 41...
Page 430: ...Setting a Unique SCSI Address the OpenVMS AXP and DEC OSF 1 AXP operating systems 16 4...
Page 461: ......